Timeout Between Decodes, Different Symbols
Parameter # 90h
Use this option in presentation mode or Continuous Bar Code Read to control the time the scanner is inactive
between decoding different symbols. It is programmable in 0.1 second increments from 0.1 to 9.9 seconds. The
default is 0.2 seconds.
To select the timeout between decodes for different symbols, scan the bar code below, then scan two numeric bar
codes from
Appendix D, Numeric Bar Codes
NOTE Timeout Between Decodes, Different Symbols cannot be greater than or equal to the Decode Session
Timeout.
Timeout Between Decodes, Different Symbols
Fuzzy 1D Processing
Parameter # F1h 02h
This option is enabled by default to optimize decode performance on 1D bar codes, including damaged and poor
quality symbols. Disable this only if you experience time delays when decoding 2D bar codes, or in detecting a no
decode.
*
Enable Fuzzy 1D Processing
(01h)
User Preferences & Miscellaneous Digital Scanner Options 4 - 15
that correspond to the desired interval, in 0.1 second increments.
Disable Fuzzy 1D Processing
(00h)