TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise
2a. Set selector switch in the OFF position.
2b. If Using Optional Hand-Held Remote: Set remote selector switch
in the OFF position to keep from draining battery.
3. Close equipment shutoff valve (see Figure 17, page 13).
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under Lighting Instructions, page 16.
2. Press control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting pilot.
After 30 seconds, release control knob. Now follow steps 9
through 11 under Lighting Instructions, page 16.
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: All remote control accessories must be purchased separately
(see Accessories, page 28). Follow instructions included with the
remote control.
NOTICE: You must light the pilot before using the
hand-held remote control unit. See Lighting Instruc-
tions on page 16.
After lighting, let pilot flame burn for about one minute. Turn control
knob to ON position. Adjust flame adjustment knob anywhere between
HI and LO. Slide selector switch to REMOTE position (see Figure 30).
Note: The burner may light if hand-held remote was on when selector
switch was last turned off. You can now turn burner on and off with
hand-held remote control unit.
IMPORTANT: Do not leave selector switch in the REMOTE or ON
position when pilot is not lit. This will drain battery.
Flame
Adjustment Knob
Control Knob
Remote Selector Switch in
in On Position
Remote Position (Optional
Hand-Held Remote Control)
Figure 30 - Setting the Remote Selector Switch, Control Knob
and Flame Adjustment Knob for Remote Operation
127119-01A
OPERATION Continued
to the OFF position.
www.Superiorfireplaces.US.com
OPTIONAL BLOWER
OPERATION
Locate blower switch by opening lower louver on fireplace insert.
Blower switch is located at lower left inside louver door.
This thermostat-controlled blower has three settings: ON, OFF and
AUTO. In the ON position, blower will operate constantly. In the
OFF position, blower will not operate. In the AUTO position, blower
will start when thermostat senses a sufficient increase in firebox
temperature.
Note: Your gas logs and thermostat blower will not turn on and off
at the same time. The fireplace insert may run for several minutes
before blower turns on. After heater modulates to pilot position,
blower will continue to run. Blower will shut off after firebox tem-
perature decreases.
Note: It is safe to operate fireplace insert with blower turned off.
However, blower helps distribute heated air from fireplace insert.