Superior VCI3032ZMN Installation And Operation Instructions Manual page 15

Unvented (vent-free) gas fireplace insert
Table of Contents

Advertisement

Grate
Prongs
Chassis
Figure 23 - Installing Log Set
Burner
Ports
Figure 24 - Installing Log Set (Top View)
Notches
Figure 25 - Installing Screen
127119-01A
INSTALLATION Continued
Crossover
Log #3
Front
Log #2
Back
Log #1
Burner
Log
Set
Screws for
Mounting
Screen
www.Superiorfireplaces.US.com
OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL
ACCESSORIES (MRC AND TRC)
Installing Remote Receiver Unit
1.
Disconnect switch wires from control valve.
2.
Remove screws attaching switch plate.
3.
Remove switch plate (see Figure 26). Discard after removing.
4.
Install remote receiver unit onto gas log heater base or set on
fireplace floor.
5.
Connect wires as shown in Figure 27.
Remote Switch
Bracket
Screw
Switch
Plate
Figure 26 - Switch Plate and Wiring Harness
White
Wire From
Receiver
Figure 27 - Connecting Wires
Ignitor
Wires
Valve
Red Wire From
Receiver
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vci3032zmp

Table of Contents