HHB CDR-850 Service Manual page 57

Professional compact disc recorder
Hide thumbs Also See for CDR-850:
Table of Contents

Advertisement

6.5.2 M-S Mix Ratio Adjustment
Test Point
CN102 - pin 3 (TE) and pin 4 (MPP)
Adjustment Point
Adjustment Value
[Procedure]
(1) Press the AUTO/MANUAL button so that "02 F3" appears on the FL display.
(2) Press the FINALIZE button for focus-in.
(3) Press the PLAY button for CAV-servo spindle kick (the status where the spindle rotates with the focus servo on and tracking servo off).
(4) Adjust with the RECORD and REC MUTE buttons until the value to be reached is obtained.
(5) Press the SET button to register the adjustment.
Once the adjustment is registered with the SET button, "?" on the FL display will disappear.
(6) Press the STOP button to stop the unit.
Note: For adjustment, use the following circuits.
39kΩ
TE
0.001µF
39kΩ
MPP
VC
0.001µF
Note: Adjustment must be done around mid-radius on a disc.
6.5.3 Tracking Offset Adjustment
Test Point
CN354 - pin 2 (TE) or CN102-pin 3 (TE)
Adjustment Point
Adjustment Value
[Procedure]
(1) Press the AUTO/MANUAL button so that "03 F6" appears on the FL display.
(2) Adjust with the RECORD and REC MUTE buttons until the above adjustment value to be reached is obtained.
(3) Press the SET button to register the adjustment.
Once the adjustment is registered with the SET button, "?" on the FL display will disappear.
TE
10 : 1
VC
10:1 probe
Note: Perform the adjustment in Stop mode.
This adjustment is possible with the low-pass filter used in adjustment 5 above attached.
RECORD button and REC MUTE button
Adjust until the value of the output signals from pin 3 (TE) and pin 4 (MPP) of CN102 are the same,
or the differential output of these signals is minimal.
CH1
10 : 1
Oscilloscope
CH2
10 : 1
10:1 probe
RECORD button and REC MUTE button
0 mV ± 10 mV