Package Content
Inspect the packaging carton. Make sure your Professional H.264 DVR is properly delivered.
Remove all items from the box and make sure the box contains the following items.
Professional H.264 DVR
Front Panel
1
Channels
2
Direction Keys
3
Shuttle/ Jog
4
COPY
5
CALL
6
DOME
7
MODE
8
PLAY/STOP
9
FREEZE
10
SEQ
11
SEARCH
12
MENU
13
ESC
14
ENTER
00P5DG600ZLEA1
Professional H.264 DVR
Setup Guide
Power Cord
1. In Live and Playback modes, press any key to view the corresponding
video in full-screen.
2. In input interface, 1~10 can be used for direct input of numbers 0~9.
3. In Dome Camera Control mode, 1 is for entering the Set/ Go preset
menu; 2 is for hiding or displaying the dome setting parameters; 11~16
is for quick access of preset points 1~6.
1. In Zoom mode, these keys function as normal direction keys.
2. In the OSD setup menu, the direction keys are used to move the cursor
to previous or next fields. To change the value in the selected field,
press UP / DOWN keys.
This is used to control playback operations.
This key is used for marking time in ezBurn™ function.
Press this key to control call monitor or 2nd main monitor.
Press this key to enter Dome Camera Control mode.
Press this key to view in full-screen or multiple window modes.
Press once to start the playback of recorded video. Press again to exit.
Press this key to freeze the current viewing screen.
Press this key to start automatic sequence display of cameras.
Press this key to search recorded video by date/time or event.
Press this key to enter the OSD setup menu.
Press this key to cancel or exit from certain control mode.
1. In OSD menu or selection interface, press these key to make the
selection or save settings.
2. In live full-screen viewing mode, press this key to view a 2× zoom
image; press it again to return.
Software CD-CMS
User's Manual
1

Advertisement

Table of Contents
loading

Summary of Contents for Okina Professional H.264

  • Page 1 Professional H.264 DVR Setup Guide Package Content Inspect the packaging carton. Make sure your Professional H.264 DVR is properly delivered. Remove all items from the box and make sure the box contains the following items. Professional H.264 DVR Power Cord Software CD-CMS User’s Manual...
  • Page 2: Back Panel

    Back Panel A RCA connector is provided to output audio associated with the Main Monitor main monitor. Audio Out Main Monitor A BNC connector is provided for connecting to a main monitor. (BNC) A BNC connector is provided for connecting to a call monitor. Call Monitor (BNC) A group of BNC connectors is offered for video input streams from installed cameras.
  • Page 3 Pin Definition of Alarm I/O & RS-485 4ch-Model / 8ch-Model: Definition Definition Definition RS485 D+ Normal Close B 15 Alarm In 5 (8ch model) RS485 D− Common Node B 16 Alarm In 6 (8ch model) Ground Normal Open B 17 Alarm In 7 (8ch model) Normal Close A Alarm In 1 18 Alarm In 8 (8ch model)
  • Page 4: Basic Setup

    Basic Setup Follow the description to set up the configuration of date/time, recording, and viewing mode of the DVR. All configurations can be set via either the DVR or DVRRemote, the remote software. Enter OSD Setup menu: • Press MENU to enter the OSD main menu. •...
  • Page 5: Network Setup

    Configure the LAN setup when you plan to use a LAN, WAN, or Internet connection without a dialup modem. It requires an Ethernet connection to a network. The default ID of your Professional H.264 DVR must be changed to avoid network conflicts.
  • Page 6: Dome Camera Control

    PC Configuration>> • On your PC, click <Start> <My Network Places> <View Network Connections> <Create New Connection> <Connect to the Internet> <Set up my connection <Connect using dial-up modem> to connect to the DVR through phone line. manually> • Give a name to the connection. Enter the phone number of the modem connected to the DVR. •...
  • Page 7: Basic Playback Operation

    • To configure the RS-485 parameters, select <System Setup> from OSD main menu, and then select <RS485 Setup>. The default Professional H.264 DVR RS-485 settings are 9600 Baud, 8 Data Bits, 1 Stop Bit and No Parity. Control Buttons of Dome Camera Control:...
  • Page 8: Using Remote Software

    Click <OK> to accept the settings and close the <Security Settings> screen. Using the Remote Software: • Start the IE and enter the IP address of your Professional H.264 DVR in the address bar. • The ActiveX controls and plug-ins dialog will show twice for confirmation; click <YES> to accept ActiveX plug-ins.
  • Page 9 NOTE: Do not enter any leading “0” characters in the address, for example, “192.068.080.006” should be entered “192.68.80.6”. NOTE: If the default trigger port 80 is changed into another one, port 81 for example, you should enter the IP address as “192.68.80.6:81”. •...
  • Page 10 DVRRemote Playback To Playback Remote Video: • Click <Play> on the main window toolbar, and then <Remote Playback> tab. • The <From> and <To> on top of the screen display the date and time from which recorded video is available for playback. •...