SYMPTOM
Excessive flue
noise
Will not light
Revised 26/05/10

MAINTENANCE

Appendix A
Fault Finding:
PROBLEM
Gap between flue and
liner too large
No light at the Infra-
Red receiver
No spark at pilot
burner.
Poor or no spark
No gas at pilot burner
Sparks, but the length
is incorrect.
No Supply Gas.
ALLURE ELECTRONIC Install Ops May2010
CORRECTIVE ACTION
Reduce to size stated on installation drawing page
6 or 7 – Item 11
Check remote light is operating when a button is
activated. Change remote batteries, Check mains
power is on
Ensure beam from the remote
Check the fuse in the back of the control Box.
Remove rear tray to access.
Check connection between electrode in pilot
assembly and lead from control
Clean any build up (Carbon) on or around the
Spark electrode.
Tracking of spark along spark electrode lead.
Replace the spark electrode
Damaged spark electrode lead, Replace
Check that isolating valves are turned on and gas
is available.
Clean the gas ways of soot or foreign particles.
Check pilot hood for blockage
Remove pilot jet and blow clean.
Check for any obstructions in the gas line that
may cause low pressure or restrict flow.
Purge gas lines.
Spark gap should be 3-4mm between the
electrode and the pilot flame hood outlet.
LPG -- Refill tank
Natural -- Check with gas supplier