Alpha InTec 26C User Instructions

Alpha InTec 26C User Instructions

Wall mounted, fan assisted, room sealed, gas fired, high efficiency condensing combination boilers

Advertisement

User's
Instructions
Alpha InTec
26C, 30C, 34C, 24X, 28X, 30GS and 40GS
Range of Wall Mounted, Fan Assisted, Room Sealed,
Gas Fired, High Efficiency Condensing Combination Boilers
For Technical help or for Service call ...
ALPHA HELPLINE Tel: 0844 871 8764
website: www.alpha-innovation.co.uk
Nepicar House, London Road,
Wrotham Heath, Sevenoaks,
Kent TN15 7RS
British Gas
Service Listed
0051
For use with Natural Gas or Propane Gas (AS SUPPLIED)
Leave these instructions with the User

Advertisement

Table of Contents
loading

Summary of Contents for Alpha InTec 26C

  • Page 1 26C, 30C, 34C, 24X, 28X, 30GS and 40GS Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers For Technical help or for Service call ... ALPHA HELPLINE Tel: 0844 871 8764 website: www.alpha-innovation.co.uk Nepicar House, London Road, Wrotham Heath, Sevenoaks,...
  • Page 2: Operating The Boiler

    Please read these instructions carefully before operating your boiler. INTRODUCTION The Alpha InTec range of high efficiency condensing boilers incorporate the latest technology in boiler design. With improved burner efficiency and reduced electrical consumption together with high quality and reliability.
  • Page 3 Once the pressure gauge is in the green area turn the taps back to the off position and the water will stop filling the system. If you happen to fill the system too much and the pressure gauge is over the green area, just bleed water from a radiator until Alpha InTec C, X and GS...
  • Page 4: Information Menu

    Further protection for the mains water supply and heating circuit must be provided separately. If Alpha external controls are fitted, a frost protection setting is incorporated into the room thermostat activating the central heating when the temperature falls below 5°C.
  • Page 5: Operational Faults

    Press the reset button (item 3 in Fig. 1) on the control panel to restart the boiler if the fault occurs again, make a note of the fault code and contact your installer or Alpha technical Helpline for further advice.
  • Page 6 Flue sensor fault Pump fault Climatic RF Error between the communication of the Batteries require replacing communication fault Climatic transmitter and boiler receiver Distance between boiler and climatic control too great Interference Object blocking signal (metallic) Alpha InTec C, X and GS...
  • Page 7: Important Notes

    The terminal on the outside wall must not be allowed to be obstructed. If it is damaged, in any way, turn the boiler off and contact your Service Engineer. Note: The Alpha InTec boilers are high efficiency condensing boilers and when operating vapour will be emitted from the terminal. This is safe and quite normal.
  • Page 8 11 OPTIONAL BOILER CONTROLS (if fitted) There is a range of controls available from Alpha to operate your boiler. In addition to the items listed below the Alpha InTec boilers are compatible with most controls available on the market. However to get the most comfort and efficiency from your boiler we recommend the Alpha Climatic controls with enhanced remote boiler functions and efficiency control.

This manual is also suitable for:

Intec 30cIntec 34cIntec 28xIntec 24xIntec 30gsIntec 40gs