Alpha 240XP User Instructions

Wall mounted, fan assisted, room sealed, gas fired combination boilers
Hide thumbs Also See for Alpha 240XP:

Advertisement

Alpha 240XP and 240XE
Wall Mounted, Fan Assisted, Room Sealed, Gas Fired
0051
User's
Instructions
Combination Boilers
For Technical help or for Service call ...
ALPHA HELPLINE
Tel: 0870 3001964
Nepicar House, London Road,
Wrotham Heath, Sevenoaks,
Kent TN15 7RS
Alpha 240XP
Alpha 240XE
For use with Natural Gas only
Leave these instructions with the User
Service Listed
G.C. No. 47 532 10
G.C. No. 47 532 11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Alpha 240XP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Alpha Alpha 240XP

  • Page 1 User's Instructions Alpha 240XP and 240XE Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers For Technical help or for Service call ... ALPHA HELPLINE Tel: 0870 3001964 Nepicar House, London Road, Wrotham Heath, Sevenoaks, Kent TN15 7RS Service Listed Alpha 240XP G.C.
  • Page 2: User Controls

    The Alpha 240XP and 240XE boilers are suitable for central heating loads of between 9.3 and 23.3 kW (31 700 and 79 500 Btu/h). The boilers will provide central heating (as required) during the 'on' times set on your clock (if fitted). Hot water is always available whenever a hot tap is opened and takes priority over the central heating.
  • Page 3: Boiler Controls

    This thermostat automatically switches the boiler off in the unlikely event of the boiler overheating. When the thermostat operates on the Alpha 240XP it turns the pilot off, and the pilot will have to be relit. Refer to the lighting instruction in section 4.
  • Page 4: Lighting Instructions

    When the temperature of the system water in the boiler reaches that set by the thermostat or the room thermostat is satisfied, the main burner is turned off and the fan stops or in the case of the Alpha 240XP the fan returns to low speed. The pump will continue to run for 5 minutes to remove any residual heat from the boiler.
  • Page 5: Important Notes

    In the event of an electrical supply failure the boiler will not operate. When the supply is restored, the boiler will return to normal operation. However, in the case of the Alpha 240XP, check that the pilot is alight by viewing through the window and if not, refer to the lighting instructions in section 4.
  • Page 6: Gas Safety Regulations

    GAS SAFETY REGULATIONS Gas Safety (Installation and Use) Regulations:- It is the law that all gas appliances are installed and serviced by a competent person, ie CORGI registered personnel. Failure to install or service appliances correctly could lead to prosecution. It is in your interest and that of safety to ensure compliance with the law.
  • Page 7 If not, use this control knob to light the pilot Alpha 240XP as per the instructions on front panel. Pilot and Burner If unable to light pilot, check gas supply is on. Viewing Window Then call Alpha Helpline OCEAN Is needle within or above SELECTOR THERMOSTAT THERMOSTAT...
  • Page 8 These instructions have been carefully prepared but we reserve the right to alter the specification at any time in the interest of product improvement. Part No. 920.047.1 © Alpha Therm Limited 1997. Manual compiled and designed by Publications Unlimited (01670) 356525 1/97/D70...