Alpha 240eco User Instructions

Wall mounted, fan assisted, room sealed, gas fired combination boiler

Advertisement

User's
Instructions
Alpha 240eco
Wall Mounted, Fan Assisted, Room Sealed, Gas Fired
Combination Boiler
For Technical help or for Service call ...
ALPHA HELPLINE
Tel: 0870 3001964
Nepicar House, London Road,
Wrotham Heath, Sevenoaks,
Kent TN15 7RS
Service Listed
Alpha 240eco
G.C. No. 47 532 05
0051
For use with Natural Gas only
Leave these instructions with the User

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 240eco and is the answer not in the manual?

Questions and answers

Summary of Contents for Alpha 240eco

  • Page 1: Combination Boiler

    User's Instructions Alpha 240eco Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boiler For Technical help or for Service call ... ALPHA HELPLINE Tel: 0870 3001964 Nepicar House, London Road, Wrotham Heath, Sevenoaks, Kent TN15 7RS Service Listed Alpha 240eco G.C.
  • Page 2: User Controls

    DESCRIPTION The Alpha 240eco boiler is a wall mounted, fan assisted room-sealed combination boiler, providing both central heating and domestic hot water at mains pressure. As supplied, the boiler is suitable for central heating systems requiring between 9.3 and 23.3 kW (31 700 and 79 500 Btu/h).
  • Page 3: Lighting Instructions

    6. INDICATOR NEONS When illuminated, the following conditions apply:- Warning light (continuously on) - blocked flue or fan fault, contact your Service Engineer. Electrical supply to the boiler is on. Boiler is supplying hot water. Boiler is supplying central heating. 7.
  • Page 4: Boiler Operation

    Use only a damp cloth and mild detergent to clean the boiler outer casing. Do not use abrasive cleaners. 6. SERVICING To maintain efficient and safe operation of your boiler, routine annual servicing is essential. For advice on servicing contact:- The Alpha Helpline: 01322 669443 or your local Gas Region.
  • Page 5: Gas Safety Regulations

    7. GAS LEAK If a fault or gas leak is suspected, turn off the gas supply. Do not touch any electrical switches, do not smoke and extinguish all naked flames. Contact your local Gas Region immediately. 8. ELECTRICAL SUPPLY The boiler requires a 240 V ~ 50 Hz supply, fused at 3 A if a 13 A 3-pin plug is used or a 5 A fuse if any other type of plug is used. To connect a plug:- The colour of the wires in the mains lead of the boiler may not correspond with the coloured markings identifying the terminals in your plug.
  • Page 7 Your optional Extended Cover Plan for 'second year' peace of mind Details of this special extended cover plan for your Alpha 240eco boiler are included on a separate leaflet which was in the envelope attached to the front of the boiler.
  • Page 8 These instructions have been carefully prepared but we reserve the right to alter the specification at any time in the interest of product improvement. Part No. 917.500.2 © Alpha Therm Limited 1995. Manual compiled and designed by Publications Unlimited (01670) 356525 07/95/D37...