Alpha 240P User Instructions

Alpha 240/280 series wall mounted, fan assisted, room sealed, gas fired combination boilers

Advertisement

Range of Wall Mounted, Fan Assisted, Room Sealed,
Gas Fired Combination Boilers
0051
User's
Instructions
Alpha 240/280
For Technical help or for Service call ...
ALPHA HELPLINE
Tel: 0870 3001964
Nepicar House, London Road,
Wrotham Heath, Sevenoaks,
Kent TN15 7RS
Alpha 240P
Alpha 240E
Alpha 280E
Alpha 280P
For use with Natural Gas only
Leave these instructions with the User
Service Listed
G.C. No. 47 532 09
G.C. No. 47 532 06
G.C. No. 47 532 08
G.C. No. 47 532 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 240P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Alpha 240P

  • Page 1 For Technical help or for Service call ... ALPHA HELPLINE Tel: 0870 3001964 Nepicar House, London Road, Wrotham Heath, Sevenoaks, Kent TN15 7RS Service Listed Alpha 240P G.C. No. 47 532 09 Alpha 240E G.C. No. 47 532 06 0051 Alpha 280E G.C. No. 47 532 08 Alpha 280P G.C.
  • Page 2: User Controls

    The Alpha 240E and 240P boilers are suitable for central heating loads of between 9.3 and 23.3 kW (31 700 and 79 500 Btu/h). The Alpha 280E and 280P boilers are suitable for central heating loads of between 9.3 and 28 kW (31 700 and 95 500 Btu/h).
  • Page 3: Boiler Controls

    This thermostat automatically switches the boiler off in the unlikely event of the boiler overheating. When the thermostat operates on the Alpha 240P/ 280P it turns the pilot off, when it operates on the 240E/280E the neon is illuminated. Press the white reset button (see Fig.
  • Page 4: Lighting Instructions

    When the temperature of the system water in the boiler reaches that set by the thermostat or the room thermostat is satisfied, the main burner is turned off and the fan stops or in the case of the Alpha 240P and 280P the fan returns to low speed.
  • Page 5: Important Notes

    In the event of an electrical supply failure the boiler will not operate. When the supply is restored, the boiler will return to normal operation. However, in the case of the Alpha 240P and 280P, check that the pilot is alight by viewing through the window and if not, refer to the lighting instructions in section 4.
  • Page 6: Gas Safety Regulations

    3.00pm (8 - 15) 3. MANUAL SWITCH Fig. 2 The clock has a manual On/Off switch which operates as follows:- Mid position Heating On/Off as set by the tappets Position I (right) Heating On continuously Position 0 (left) Heating Off continuously Alpha 240/280...
  • Page 7 If this light is not on Turn selector Turn to See C to ..maximum Alpha 240E and Alpha 280E If this light is not on Open hot tap fully and this See C light should come on If no hot water - call...
  • Page 8 These instructions have been carefully prepared but we reserve the right to alter the specification at any time in the interest of product improvement. Part No. 920.033.2 © Alpha Therm Limited 1999. Manual compiled and designed by Publications 2000 - Tel: (01670) 356211 11/99/D101...