Meyer Sound MILO 120 Operating Instructions Manual page 42

High-power expanded coverage curvilinear array loudspeaker m series
Hide thumbs Also See for MILO 120:
Table of Contents

Advertisement

APPENDIX B
AUDIO INPUT
Type
Max. common mode range
Connectors
Input impedance
Wiring
DC Blocking
CMRR
RF filter
TIM filter
Nominal input sensitivity
Input level
AMPLIFIERS
Amplifier type
Output power
THD, IM TIM
Load capacity
Cooling
AC POWER
AC power connector
Voltage selection
Safety agency rated
operating voltage
Turn on/turn off points
Current Draw
Idle current
Max. long-term continuous
current (>10 sec)
Burst Current (<1 sec)
Note: AC power cabling must be of sufficient gauge so that under burst current RMS conditions, cable transmission
losses do not drop voltage below specified operating range at the speaker.
Ultimate Short-Term Peak
Current Draw
Inrush Current
RMS NETWORK
36
Differential, electronically balanced
±15 V DC, clamped to earth for voltage transient protection
Female XLR input with male XLR loop output or VEAM
10 kΩ differential between pins 2 and 3
Pin 1: Chassis/earth through 220 kΩ, 1000 pF, 15 V clamp network to provide virtual
ground lift at audio frequencies
Pin 2: Signal +
Pin 3: Signal -
Case: Earth ground and chassis
None on input, DC blocked through signal processing
>50 dB, typically 80 dB (50 Hz – 500 Hz)
Common mode: 425 kHz
Differential mode: 142 kHz
<80 kHz, integral to signal processing
0 dB V (1 V rms, 1.4 V pk) continuous is typically the onset of TPL limiting for noise and
music.
Audio source must be capable of producing a minimum of +20 dBV (10 V rms, 14 V pk)
into 600 Ω in order to produce maximum peak SPL over the operating bandwidth of the
loudspeaker
Complementary power MOSFET output stages (class AB/H)
3560 W (four channels; 2 x 1125 W, 1 x 560 W, 1 x 750 W)
Note: Amplifier wattage rating is based on the maximum unclipped burst sine-wave rms
voltage the amplifier will produce in to the nominal load impedance low, mid and very high
channels 67 V rms (95 V pk) into 4, 6 and 8 ohms.
< .02%
4 Ω low and mid; 8 Ω high channel; 6 Ω very high channel
Forced air cooling, 4 fans total (2 ultrahigh-speed reserve fans)
250 V AC NEMA L6-20 (twistlock) inlet, IEC 309 male inlet, or
VEAM all-in-one connector (integrates AC, audio and network)
Automatic, two ranges, each with high-low voltage tap (uninterrupted)
95 V AC – 125 V AC, 208 V AC - 235 V AC, 50/60 Hz
85 V AC – 134 V AC; 165 V AC - 264 V AC
1.1 A rms (115 V AC), 0.55 A rms (230 V AC), 1.3 A rms (100 V AC)
11.2 A rms (115 V AC), 5.6 A rms (230 V AC), 12.9 A rms (100 V AC)
14.4 A rms (115 V AC), 7.2 A rms (230 V AC), 16.6 A rms (100 V AC)
32 A rms (115 V AC), 16 A rms (230 V AC), 37 A rms (100 V AC)
7 A rms (115 and 110 V AC), 10 A rms (230 V AC)
Equipped for two conductor twisted-pair network, reporting all operating parameters of
amplifiers to system operator's host computer.

Hide quick links:

Advertisement

Table of Contents
loading