TO INSURE BOTH SAFE AND TROUBLE-FREE PERFORMANCE, WE STRESS THAT ALL PERSONNEL THAT WILL BE INVOLVED WITH YOUR NEW UNIVEX MEAT GRINDER MUST READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE ATTEMPTING TO OPERATE THIS UNIT. ------------------------- WE APPRECIATE YOUR COOPERATION AND YOUR BUSINESS.
Or visit us on-line at www.univexcorp.com under service agents. The UNIVEX Model MG22 Meat Grinder consists of a 1 HP electric motor power base which drives a bell-shaped meat grinder designed to utilize industry standard #22 knives and a full range of #22 grinding plates.Included as standard equipment is a carbon steel knife, a 3/16 grinding plate, an...
WIPE DOWN THE EXTERIOR OF THE DRIVE UNIT ONLY, NEVER HOSE DOWN OR IMMERSE THE DRIVE UNIT IN WATER. DO NOT ATTEMPT TO SERVICE THE DRIVE ASSEMBLY. PLEASE CONTACT UNIVEX CORPORATION FOR THE NUMBER OF THE NEAREST AUTHORIZED SERVICE AGENT IN YOUR AREA FOR ADJUSTMENTS OR REPAIR.
Page 6
OVERALL VIEW OF THE MG22 FIGURE 1 POWER UNIT SAFETY GUARD POWER CORD STOMPER GRINDER MOUNTING KNOB FEED PAN POWER SWITCH FEED PAN SUPPORT TUB CLIP TUB & COVER (NOT SHOWN) GRINDER ASSEMBLY PAGE 4...
INSTALLATION • This is a table-top unit. The grinder may be secured to a table top via the shipping bolt threaded holes on the bottom of the power drive housing. • Insure that the grinder is located on a flat, level and stable surface. There should be sufficient clearance around the grinder for safety and ease of operation.
CLEANING INSTRUCTIONS 1. Turn the grinder off and disconnect the power supply cord. 2. Disassemble the grinder in the reverse order of the assembly instructions: Remove the storage container and feed pan. Remove the ring, plate and knife. WARNING: The knife is very sharp and can cut fingers. Slide the worm assembly from the grinder housing.
Warranty The Univex MG22 Meat Grinder carries a one-year, on-site parts and labor warranty against any defects in materials or workmanship. The one-year period begins on the date of purchase by the end user and remains in full effect provided the unit is used properly and in accordance with our instructions.