Temperature-Pressure Relief Valve - Optional Location; Filling The Water Heater - Kenmore 153.31206 Owner's Manual

Electric water heater
Table of Contents

Advertisement

Installation
Instructions
(cont'd)
Temperature-Pressure
Relief
Valve - Optional
Location
An optional temperature-pressure
relief valve location is provid-
ed on the jacket top andcentered
between the COLD water
inlet and the HOT water outlet.
If the top location is preferred, the temperature-pressure
relief
valve in the side location and the counter-sunk
plug in the top
location can be interchanged.
Be sure to use new pipe joint compound
or put two to three
turns of teflon tape around the threaded ends of the tempera-
ture-pressure
relief valve and counter-sunk
plug when re-
installing these parts.
WARNING
-_is *_ter heater i sprovided witha combleafi_ Temperature-Pressure
Relief Valvelistedascomplying i t_ theelandardfer Relief Valve_and Automatic Gas Shutoff
Devices ferHotWater Supply S ystems, ANS721.221_6 andthecoderequirements
ofASME.
YourIcca_ j urisdiclfendi authorby, while maeda_ng theuseof a Tefederatum-Pres_Jre
ReliefVdi_
complying wi_ ANSZ21.22andASME,mayrequire a vdi_ model d ifferent frc_n the onehJmiSt_d
withthe waterbeater,
C_pliance with such_
reqlerernenfe
mustbe satisfied bytheleuteller o renduserofthewater
heater w itha locally prescribed Temberthure-Pressure
RdlefValveina_lled inthe designated open-
leginthewaterhether.
'festdi_ T ernperatu_Pre_sure
protective eduipmeut r equired b ylocal c odes, b utrotlesstbencom-
elnatic_T_Cnberofum-Pressure
Relfef V ak,_certified as meeting thereqleremen_s
to_Rofed
a,xiAutomabe GasShutoff De_ces forHof-Water Supp_ 8y_ras, N_S2:2122-19_bya national*
ly recognized testing kCut_ry thatrn_nteles p ededic inspeci_of production of listed equipment
matedais. _
valvemust be beentbe, p rovided withte_ng,or other*tseinstut_ so_at dis-
dlargecanexit onlyv, s hin6 leches of_ove, or _ any d_tence bdowtbesttu_terdi floor, a nd_
conlaut any_vedect _.alpar_"
Forsafeppertefe_ of tbewa_ heater, 1he Relief V alvemuut notberemoved o rplugged.
See manual h eading. "T#raperelure*Pressure
Relief Valve'fe,"i_stel_le_acidmaintenance of
Relief Valve, discharge line anduthersafely preceubens.
COLD
TEMPERATURE-
PRESSURE
SHUTOFF
VALVE
DISCHARGE
(Do not cap
or plug)
Filling the Water
Heater
To fill the water heater with water:
Close the water heater drain valve by turning the handle to
the right (clockwise). The drain valve is on the lower front of
the water heater.
Open the cold water supply valve to the water heater.
NOTE: The cold water supply valve must be left open
when the water beater is in use.
To insure complete filling of the tank, allow air to exit by
opening the nearest hot water faucet. Allow water to run
until a constant flow is obtained. This will let air out of the
water heater and the piping.
I
A CAUTION
1
Never use this water heater unless it is completely full of |
water. To prevent damage to the tank and heating ale- |
ment, the tank must be filled with water. Water must
flow from the hot water faucet before turning "ON"
|
power.
|
Check all new water piping for leaks. Repair as needed.
Converting
the Lower
Element
These instructions only cover the conversion of the convertible
element, read this entire manual before attempting to install or
operate the water heater. The water heater is factory set to oper-
ate at 3800 watts. The lower element can he converted to oper-
ate at 5500 watts. Refer to the "Facts to Consider About the
Location" section.
The Upper Element, (if a double element model) is a conven-
tional 3800 watt element which only operates at its rated
wattage on 240 volts. (See rating plate on waterheater).
The Lower Element of the water heater can be converted from
operation at 3800 watts to 5500 watts on a 240 volt system.
If after reading these instructions and this manual, if you do not
understand any portion, call Sears Service Center.
AWARNING
Before making the conversion to 5500 watts, check the
(I) power supply...must be 240 volts, (2) wiring...10 gauge
AWG, Type TW, 60C or equivalent,
and (3) Circuit
breakers or fusing_capable of 30 amp loading. Also, the
installation must conform with this Manual, local codes
and electric utility rules. FAILURE TO COMPLY CAN
RESULT IN DEATH,
SERIOUS
BODILY INJURY OR
PROPERTY DAMAGE.
IR GAP
10