20 to 120 Gallons. Input rating of 12 Kw or lessat a voltage no greater than 250 _WARNING READ THE GENERAL SAFETY SECTION BEGINNING AND THEN THIS ENTIRE HANUAL ING THIS WATER HEATER. and Co., Hoffman Estates, www.sears.com ELECTRIC...
Compliance with such local requirements must be satisfied by the installer or end user of the water heater with a locally pre- scribed temperature-pressure relief valve installed in the desig- nated opening in the water heater in place of the factory fur- nished valve.
Materials and Basic Tools Needed ... Materials Needed ... Basic "lbols ... Installation Instructions Removing the Old Water Heater..Facts m Consider About the Location ... Facts m Consider About the Convertible Water Piping ... T&P Valve and Pipe Insulation ...
21" 153.318131 24" *Wiring size based on standard 60°C. copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electrical code. The installation must conform with the instructions in the a Sears water heater.
SCREW DRIVER PHILLIPS SCREWDRIVER PIPE DOPE (SQUEEZE TUBE) roll of teflon tape (Use only on water connec- tions) WATER HEATER HEAT TRAPS HELP REDUCE HEAT LOSS DUE TO THERMAL SYPHONING ADDITIONAL WHEN Tubing Cutters or Hacksaw Propane Torch Soft Solder...
Page 6
Instructions turned supply is Mineral buildup or sediment may have accumulated in J electric supply the old water heater. This causesthe water heater to be I much heavier than normal and this residue, if spilledout, could causestaining. green ground screw...
WATER HEATERS EVENTUALLY the water heater must be accomplished in such a man- ner that if the tank or any connections should leak, the flow of water will not cause damage to the structure. When such locations cannot be avoided, a suitable drain...
Compliance with such local requirements by the installer or end user of the water heater with a locally prescribed temperature-pressure relief valve installed in the designated opening in the water heater in place of the facto- ry furnished valve.
These instructions only cover the conversion of the convertible element, read this entire Manual before attempting to install or operate the water heater. The water heater is factory set to oper- ate at 3800 watts. The element can be converted to operate at 5500 watts.
Page 11
Element (cont'd) 2. The convertible element is located behind the large access panel of the water heater. Remove the two screws securing the access panel, and remove panel. 3. Remove tape and the insulation pad to expose the terminal cover over the element.
Instructions 12. Complete wiring to water heater, or if completed, Never use this water heater unless it is completely full of water. To prevent damage to the tank and heating ele- ment, the tank must be filled with water. Water flow from the hot water power.
If you are not familiar with electric codes and practices, or if you have any doubt, even the slightest doubt, in your ability to con- nect the wiring to this water heater, obtain the service of a com- petent electrician. Contact your Sears salesperson to arrange for a professional electrician.
Instructions section. • Will a water leak damage anything? See "Facts to Consider About the Location" section. • Are the cold and hot water lines connected to the water heater correctly? See "Water Piping" instructions in the "Installation lnstrucnons section.
(M- j_ ) to_'ecrease the tempera- ture setting, with a small flat tip screwdriverT- 1. _Ihrn"OFF" the electrical power ro the water heater at the junction box. HAZARD OF ELECTRICAL SHOCK! Before removing any access panelsor servicingthe water heater, make sure I the electrical supplyto the water heater is turned "OFF".
• Connect a hose to the drain valve and terminate to an adequate drain or outdoors. • OPEN the water heater drain valve to allow for tank draining. NOTE: If the water heater is going to be shut down and...
2. "Iiirn off"the water supply to the water heater at the water shutoff'valve or water meter. 3. Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors. Open the water heater drain valve.
Page 18
11. Close the water heater drain valve by turning the handle to the right (clockwise). The drain valve is on the lower front of the water heater.
Before calling for repair service, read the Start Up Conditions and Operational Guide of this manual. If a condition persists or you are uncertain about the operation of the water heater, let a qualified person check it out. Contact SEARS Repair Services at 1-800-4-MY-HOME 4663). (cont'd)
The water within the water heater tank expands as it is heated and increases the pressure of the water system. If the relieving point of the water heater's temperature-pressure valve will relieve the excess pressure.
Conditions SMELLY WATER In each water heater there is installed at least on anode rod (see parts section) for corrosion protection of the tank. Certain water conditions will cause a reaction between this rod and the water. The most common complaint associated with the anode rod is one of a "rotten egg smell".
Review and check piping installation. cold water line is connected to the cold water inlet to the water heater and the hot water line to the hot water outlet on the water heater. • Make sure the electrical supply to your water heater is "ON".
Water from the drain valve may be due to the valve being opened slightly. *The drain valve may be leaking at the tank fitting. *Water in the water heater bottom or on the floor may be from condensation, loose connections or the tempera- ture-pressure relief valve.
Parts Order KENMORE THE ECONOMIZER _ 6 TABLE TOP ELECTRIC WATER HEATERS MODEL NUMBERS: 153.318031 27 Gal. 153.318131 40 Gal. NOTE: This water heater is equipped with a factory installed con- vertible element, which can be operated at 3800 watts or 5500 watts.
Page 27
# Not Illustrated Now that you have purchased this water heater, should a need ever exist for repair parts or service, simply contact any SEARS Service Center or call 1-800-4-MY-HOME (1-800-469-4663). Be sure to provide all pertinent facts when you call or visit.
"]['hiswarranty gives you specific legal rights and you may also have other rights which vary from state to state. The price of your water heater does not include a free checkup service call. On water heater installations arranged by Sears, Searswarrants the installation.