Points To Note About The Fingerprint Utility - Toshiba tecra s3 User Manual

Portable personal computer
Hide thumbs Also See for tecra s3:
Table of Contents

Advertisement

Operating Basics
The following illustrations show the correct way to slide your finger over the
recognition sensor.
Align the finger and sensor like the drawings.

Points to note about the Fingerprint Utility

The user should back up the user profile information when using the
functions provided in this software to encrypt files or folders. If this software
or the user information is deleted without backing up the user profile
information, the encrypted files will no longer be accessible. In addition, if
the backup data is not used, the user will not be identified as the same user
even if the same name is used again in user enrolment.
Please refer to the following procedures to back up.
Double-click on the OmniPass icon in the task tray, select the
UserManagement tab, select Import/Export User, click on Export an
OmniPass user profile, carry out fingerprint authentication, specify the
destination folder and filename to save the profile, and save the file.
If Windows XP Professional's file encryption function EFS (Encryption File
System) is used to encrypt a file, the file cannot be further encrypted using
the encryption function of this software.
If the fingerprint sensor and Trusted Platform Module (TPM) security are
used as identification devices, install and configure the Infineon TPM
Professional package first before configuring the fingerprint utility. Please
refer to the TPM (Trusted Platform Module) Installation Guide for the
installation and configuration methods for TPM.
In the help file, it is stated that this software's Password Replacement
function can be used for the Internet and general applications. However,
the Internet Password Replacement function in the fingerprint utility
provided in this computer can only be used with IE (Internet Explorer).
There is a section on Strong Logon Security in the help file, but the
function is not available in the fingerprint utility provided in this computer.
The sound during Log Off Current User (when logging off from OmniPass)
cannot be set to off even if the No Audio Prompts configuration is set in
Audio Settings. If you wish to turn it off, remove the settings for wav files in
the event settings of the sound events section of the Sound and Audio
Device Property in the control panel.
User's Manual