Split system and package units
Table of Contents

Advertisement

SKY
7.3 Wiring the Outdoor Unit
• Locate the terminal box cover according to the following figures.
• Remove the outdoor unit side cover.
• Connect the wires to the terminals, in accordance with the color coding and the
suitable wiring diagrams.
• Connect the outdoor sensor cable, making sure the connector is properly inserted.
• Secure the inter-unit electrical cable to the outdoor unit using the clamps.
• Make sure that all screws and wires are properly fastened. Loose wires or connections
can cause damage and present a fire hazard!
• Reassemble the side cover.
7.3.1 Outdoor Unit Terminal Box
7.4 Wiring the Indoor Unit
• Locate the terminal box cover according to the following figures.
• Remove the indoor unit side cover.
• Connect the wires to the terminals, in accordance with the color coding and the
suitable wiring diagrams.
• Make sure that all connections are properly inserted and fastened.
• Make sure that all screws and wires are properly fastened. Loose wires or connections
can cause damage and present a fire hazard!
• Reassemble the side cover.