Figure 22: Mounting - Air Terminal For Tower And Pole Deployments - Redline Communications RDL-2000 Installation Manuallines

Broadband wireless radio platform
Hide thumbs Also See for RDL-2000:
Table of Contents

Advertisement

RDL-2000
The following recommendations are general industry practices:
The antenna mast/tower must be connected to the master earth ground.
-
It is recommended to pre-assemble and test the RDL-2000 equipment (RDL-
-
2000, mounting bracket, and antenna) and connection wiring before final
installation of the units. Mount the pre-assembled RDL-2000 on the antenna
mast.
Direct grounding from the RDL-2000, the mounting bracket, the antenna, and
-
the Ethernet cable surge protection to the same ground bus on the building
should be provided. Terminate ground wires using the grounding screws
provided on the RDL-2000 and the antenna mounting bracket.
A lightning arrestor should be installed in series with the Ethernet cable as
-
close to the RDL-2000 unit as practical. The grounding wire should be
connected to the same termination point used for the tower or mast.
A lightning arrestor should be installed in series with the Ethernet cable at the
-
point of entry to the building. The grounding wire should be connected to the
same termination point used for the tower or mast.
. If AC PoE is used, the AC wall outlet ground for the indoor POE adapter
-
should be connected to the building grounding system.
70-00144-01-01
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
Installation Guidelines

Figure 22: Mounting - Air Terminal for Tower and Pole Deployments

Proprietary Redline Communications © 2011
Page
34
of 52
March 9, 2011

Advertisement

Table of Contents
loading

Table of Contents