Avoid sharp bends in the ground wire.
-
The installation site should have had an external ground ring or bus bar.
-
Above ground wire must be #2-6 AWG when interconnecting ground rings and #6
AWG (minimum) for grounding equipment and any metal objects
-
Below ground wire must be #2 AWG (minimum).
-
Ground rods must be 8 feet long (minimum) and 5/8-inch in diameter. Rods must
extend 3 feet below any adjacent basement/vault.
-
A grounding block should be installed where cables enter the building.
This section describes mounting of the RDL-2000, recommendations for grounding and
line protection equipment, and rough alignment of the antenna.