Download Print this page

Focal Point ND-18D1 Augusta Installation And User Instructions page 3

Wall mounted electric fire electric stove

Advertisement

6.0 OPERATING THE APPLIANCE
Check that the fan outlet is not covered or obstructed in
any way, and ensure the power to the fire is switched on.
The appliance controls are concealed behind a panel on the
front of the heater.
'a'
Thermostat
'b'
Fan (without heat)
'c'
Heat 900W
'd'
Heat 900W
'e'
Flame effect on/off
'f '
Flame effect dimmer
Switch 'e' turns on the flame effect. Knob 'f' controls with brightness of the flame effect. Turn knob 'f' until the desired effect is
achieved.
Switch 'b' controls the fan function. The fan may be operated without heat, or without the flame effect. With the fan running, switch
'c' turns on heat setting 1 (900W), and switch ''d' controls heat setting 2 (1800W). The fan must be switched on for the heat set-
tings to work. The fan and heating functions can be operated with or without the flame effect. The appliance is fitted with a ther-
mostat. To adjust the thermostat, turn knob 'a' until the desired room temperature is achieved.
7.0 SAFETY CUTOUT SYSTEM
This appliance has a safety cutout system fitted which will activate if the air inlets or outlets are obstructed. For safety reasons
the fire will NOT switch on again automatically, the following procedure must be carried out before the fire can be operated.
NOTE: The visual effect will remain operational if the cutout is activated, only the fan heater is prevented from working.
Switch OFF the appliance at the wall socket or outlet. Leave the fire OFF for a period of no less than 10 minutes, ensuring all
obstructions are removed. Switch the appliance ON at the wall. Ensure the appliance is turned ON at the control switches. If
the fire fails to operate correctly, repeat the above procedure. If an attempt to switch on the appliance is made before the safe-
ty cutout has reset, the appliance may cutout for a further period of time. If the sequence has been followed correctly and the
appliance still fails to function, check the fuse in the wall outlet. If this is not the cause, call an electrician or maintenance engineer.
8.0 MAINTENANCE
ALWAYS DISCONNECT THE APPLIANCE FROM THE MAINS SUPPLY BEFORE
Excluding lamps and fuses, use only genuine spare parts available from your supplier. Replacement lamps must be of the same
wattage and specification as those stated in Section 2.0 Appliance Data.
Replacing the light bulbs.
1) Disconnect the appliance from the mains.
2) Open the door.
3) Remove the three screws at the front of the decorative fuel bed. Remove the fuel bed clamp.
4) Lift up the decorative fuel bed.
5) Two bulbs are located under the decorative fuel bed.
6) Unscrew and replace the bulb(s) using only 25W E14 type.
7) Re-assembly is the reverse of removal.
9.0 CLEANING
There is no specific requirement for care of the fire other than a regular cleaning of the general appliance.
The decorative MDF casing is not removable for cleaning. A wipe with a dry cloth is normally sufficient. DO NOT use abrasive
cleaners as they can damage the finish. Brass and silver parts of the fire may be cleaned using a appropriate metal polishes.
10.0 SPARES
Refer to Section 2.0 Appliance Data for lamp and fuse specification. Excluding lamps and fuses, use only genuine manufacturers
spare parts available from your supplier.
'a'
UNDERTAKING ANY MAINTENANCE.
3
'b'
'c'
'd'
GB IE
'e'
'f '
©
2011 Focal Point Fires plc.

Advertisement

loading

This manual is also suitable for:

Nd-18d1 es2000