3-6. The adjustment item which in necessary in part exchange
IC501
Oscillation
Frequency
Adjustment
COMPL PWB CP-1
(636 089 9087)
COMPL PWB ST-1
(636 089 9100)
COMPL PWB TB-1
(636 089 9117)
COMPL PWB TB-2
(636 089 9124)
LENS ASSY
(645 080 4755)
3-7. Adjust Specifications
[CP1 board (Side B)]
Note:
1. Frequency adjustment is necessary to repair in the CP1
board and replace the parts.
Preparation:
1. Remove the cabinet front. You can see VR501 and CL501
in the CP1 board.
2. Insert the SD card.
3. Turn on the power switch, and set the camera mode.
1. IC501 Oscillation Frequency Adjustment
CL501
Measuring Point
Measuring Equipment
Frequency counter
ADJ. Location
VR501
499.5 ± 1 kHz
ADJ. Value
Adjustment method:
1. Adjust with VR501 to 499.5 ± 1 kHz.
CCD White
Lens
AWB
Point Defect
Detect
Adjustment
Adjustment
Adjustment
CL501
VR501
CCD Black
Point And White
Factory
Point Defect
Cord
Detect
Setting
Adjustment In
Lighted
2. Lens Adjustment
Camera
Preparation:
POWER switch: ON
If using a ready-made collimator, set to infinity.
Note:
Do not vibrate during the adjustment.
Adjustment method:
1. Set the camera 0 cm from the collimator. (Do not enter any
light.)
2. Set the camera so that it becomes center of the screen in
the collimator.
3. Double-click on the DscCalDi.exe.
4. Click the Focus, and click the Yes.
5. Lens adjustment value will appear on the screen.
6. Click the OK.
– 16 –