II INSTALLATION

This unit must be installed, inspected, calibrated and
serviced by qualified and/or certified and licensed
service personnel - you may void your Keating
warranty if installation is not completed per local,
national and Keating specifications. Contact your
dealer for assistance.
INSTALLATION
Installation must conform with local codes or, in
absence of local codes, with the current National
Electrical Code ANSI/NFPA 70 or Canadian Electrical
Code CAN22.2 as applicable.
DAMAGE DURING
SHIPMENT
The griddle has been assembled, tested and inspected
at the factory. Upon arrival, the complete griddle should
be checked for any damage that may have occurred
during shipment.
The carrier is responsible for all damage in transit
whether visible or concealed. Do not pay the freight bill
until the griddle has been thoroughly checked for
damage. If concealed damage is found later, contact
the carrier immediately to file a claim.
What to do if equipment arrives damaged:
VISIBLE LOSS OR DAMAGE -- Be certain to note this
on the freight or express receipt and have it signed by
the delivery person.
FILE CLAIM FOR DAMAGES IMMEDIATELY --
Regardless of extent of damage.
CONCEALED LOSS OR DAMAGE -- If damage is
noticed when equipment is unpacked, notify the freight
company immediately, and file a "concealed damage
claim". This MUST be done immediately. Be sure to
retain the shipping container for inspection.
Keating does not assume responsibility for Loss or
Damage incurred in transit.

POSITIONING

The griddle must be placed under an exhaust hood
with a fire retardant system. Your ventilation hood,
when installed, must conform to the current
ANSI/NFPA 96 standard. ALL connections and
placement must comply with local and national codes.
It is the responsibility of the owner and local installer to
comply with these regulations when installing the
griddle.
NOTE: NOT FOR OUTDOOR INSTALLATION

LEVELING

Your MIRACLEAN
®
Griddle will operate at its highest
efficiency when properly leveled. Place a level on the
griddle plate from side to side. For griddles on legs, the
bottom foot of the leg is adjustable. Turn clockwise to
decrease height or counterclockwise to increase height
until level. For griddles on stands with casters, the
casters are adjustable by loosening the jam nut and
turning the caster in or out. When the desired level is
reached, tighten the jam nut. Adjustments of more than
3/4" are not recommended on any caster. The same
procedure should be followed to the level the griddle
from front to back.
Figure 2-1
Leveling Griddle
RESTRAINING
for griddle installations on stands with casters, casters
and jam nuts must be completely tightened. Adequate
means must also be provided to limit the movement of
the appliance.
The restraint must be attached to the rear of the griddle
as close as possible to the center line width and the
bottom of the cabinet back to allow the restraining bolt
to be anchored to the cabinet back between the cabinet
bottom and inner liner to ensure positive support to
restrain griddle movement.
IF DISCONNECTION OF THE
WARNING
RESTRAINT IS NECESSARY, IT
MUST BE RECONNECTED WHEN
THE MIRACLEAN® GRIDDLE IS
RETURNED TO ITS ORIGINALLY
INSTALLED POSITION.
Do not stand, sit or
lean on equipment.
ELECTRICAL
CONNECTION
The Keating Electric MIRACLEAN
with a three wire terminal block for customer
connections. Compare the griddle terminal connections
to the appropriate wiring diagram for the griddle (see
2
®
Griddle is equipped

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Miraclean 2000 series

Table of Contents