  • Page 1                           PTZ SETUP GUIDE    For:  PelcoD 2400bps on RS485                      ™ © 2008 RhinoCo Technology Pty. Ltd.  9 Hannabus Place, McGraths Hill, NSW Australia 2756  http://www.rhinosecruity.com ...
  • Page 2 Introduction The purpose of this guide is assist in the installation, setup and use of any PTZ with any PTZ Keyboard or compatible DVR. We recommend using only RS485 with PelcoD on 2400Bps upto 16 IDs, as this is the most common and universal format. If you cannot run a 2400Bps baudrate then we recommend using 4800Bps, in which case you will have to consult you user manual for more assistance.
  • Page 3: Table Of Contents

    Contents PTZs: VSPTZ55(W) Page 1. VSSAM-SPD3300 Page 2. VSJVC-TKC686(WP)E Page 3. VSPTZ7722B Page 4. Keyboards: VSPTZKB Page 5. VSSAM-SCC3100A Page 6. DVRs: DVRPLATINUM Page 7. DVRDIAMOND Page 8. DVRWGUARD Page 9. DVRAPEX Page 10.
  • Page 4: Vsptz55(W)

    Securview VSPTZ55(W) PTZ on ID01 and Pelco-D at 2400Bps For Power Connection: 24vAC+ Red 24vAC- Black For 2 wire RS485 Connection: RS485+ Orange (Rx+) RS485- Yellow (Rx-) ID Setting Switch Protocol Setting © Copyright 2009 RhinoCo Technology Page 1...
  • Page 5 Samsung SPD-3300 PTZ on ID01 and Pelco-D at 2400Bps For Power Connection: 24vAC+ 24vAC- For 2 wire RS485 connection: RS485+ RS485- PTZ ID SW1 – 0 SW2 – 1 SW3 – 2 © Copyright 2009 RhinoCo Technology Page 2...
  • Page 6 JVC TK-C686WPE PTZ on ID01 and Pelco-D at 2400Bps For Power Connection: 24vAC+ Red 24vAC- Black For 2 wire RS485 connection: RS485+ Orange/White (Rx+) RS485- Black/White (Rx-) Setting Switch Machine ID Option Switch To access to onboard menu: Press PRESET > 9 > 5 > ENTER MENU = Close SET = Open ©...
  • Page 7: Vsptz7722B

    Securview VSPTZ7722B PTZ on ID01 and Pelco-D at 2400Bps For Power Connection: 24vAC Ground 24vAC -OR- 12vDC Socket For 2 wire RS485 Connection: RS485+ (Rx+) RS485- (Rx-) ID Setting Switch Simplex/Duplex Setting S2 Setting S1 Setting © Copyright 2009 RhinoCo Technology Page 4...
  • Page 8: Vsptzkb

    Securview VSPTZKB on ID01 and Pelco-D at 2400Bps For Power Connection: 12vDC Socket For 2 wire RS485 connection: RS485+ (Tx+) RS485- (Tx-) There are 2 sets are Tx- and Tx+, either can be used. Protocol Switch © Copyright 2009 RhinoCo Technology Page 5...
  • Page 9: Vssam-Scc3100A

    Samsung VSSAM-SCC3100A on ID01 and Pelco-D at 4800Bps Note: The Samsung VSSAM-SCC1300A does not support a baudrate of 2400bps, and it is therefore necessary to run any PTZ cameras on 4800bps or above. For Power Connection: 12vDC+ 12vDC- For 2 wire RS485 connection: Press ‘PTZ’...
  • Page 10: Dvrplatinum

    Securview DVRPLATINUM on ID01 and Pelco-D at 2400Bps For 2 wire RS485 connection on rear of DVR with additional cable: RS485+ Red (Tx+) RS485- White (Tx-) Set the DVR to use the inbuilt RS485 by going to ‘Config’ > ‘System’ > ‘Serial’, and setting the Odcap to PTZ.
  • Page 11: Dvrdiamond

    Securview DVRDIAMOND on ID01 and Pelco-D at 2400Bps For 2 wire RS485 connection on rear of DVR: RS485+ D+ (Tx+) RS485- D- (Tx-) Set the DVR to use the PTZ by going to ‘MENU’ > ‘SYSTEM’ > ‘CAMERA’ > ‘PTZ SETUP’, and setting ‘Camera #’...
  • Page 12: Dvrwguard

    Securview DVRWGUARD on ID01 and Pelco-D at 2400Bps For 2 wire RS485 connection on rear of DVR: RS485+ (Tx+) RS485- (Tx-) Set the DVR to use the PTZ by going to ‘MENU’ > ‘DEVICE’ > ‘PTZ’, and setting ‘CH #’ to Protocol: PELCO D, Baudrate: 2400bps, and ID: 1.
  • Page 13: Dvrapex

    Securview DVRAPEX on ID01 and Pelco-D at 2400Bps For 2 wire RS485 connection on rear of DVR: RS485+ (Tx+) Com4 RS485- (Tx-) Com4 Set the DVR to use the PTZ by going into ‘MENU’ > ‘DEVICE’ > ‘CAMERA’. Then set ‘CAM SELECT #’ to: PTZ PORT: COM4 RS485 and PTZ ID: 1.