Page 2
Introduction The purpose of this guide is assist in the installation, setup and use of any PTZ with any PTZ Keyboard or compatible DVR. We recommend using only RS485 with PelcoD on 2400Bps upto 16 IDs, as this is the most common and universal format. If you cannot run a 2400Bps baudrate then we recommend using 4800Bps, in which case you will have to consult you user manual for more assistance.
Samsung VSSAM-SCC3100A on ID01 and Pelco-D at 4800Bps Note: The Samsung VSSAM-SCC1300A does not support a baudrate of 2400bps, and it is therefore necessary to run any PTZ cameras on 4800bps or above. For Power Connection: 12vDC+ 12vDC- For 2 wire RS485 connection: Press ‘PTZ’...
Securview DVRPLATINUM on ID01 and Pelco-D at 2400Bps For 2 wire RS485 connection on rear of DVR with additional cable: RS485+ Red (Tx+) RS485- White (Tx-) Set the DVR to use the inbuilt RS485 by going to ‘Config’ > ‘System’ > ‘Serial’, and setting the Odcap to PTZ.
Securview DVRDIAMOND on ID01 and Pelco-D at 2400Bps For 2 wire RS485 connection on rear of DVR: RS485+ D+ (Tx+) RS485- D- (Tx-) Set the DVR to use the PTZ by going to ‘MENU’ > ‘SYSTEM’ > ‘CAMERA’ > ‘PTZ SETUP’, and setting ‘Camera #’...
Securview DVRWGUARD on ID01 and Pelco-D at 2400Bps For 2 wire RS485 connection on rear of DVR: RS485+ (Tx+) RS485- (Tx-) Set the DVR to use the PTZ by going to ‘MENU’ > ‘DEVICE’ > ‘PTZ’, and setting ‘CH #’ to Protocol: PELCO D, Baudrate: 2400bps, and ID: 1.
Securview DVRAPEX on ID01 and Pelco-D at 2400Bps For 2 wire RS485 connection on rear of DVR: RS485+ (Tx+) Com4 RS485- (Tx-) Com4 Set the DVR to use the PTZ by going into ‘MENU’ > ‘DEVICE’ > ‘CAMERA’. Then set ‘CAM SELECT #’ to: PTZ PORT: COM4 RS485 and PTZ ID: 1.