OPERATION INSTRUCTIONS FOR
ROLLING CODE ALARM: RA96
INSURANCE APPROVED SPLIT SYSTEM MODEL WITH
ENGINE IMMOBILISATION AND BOOT RELEASE
MADE IN AUSTRALIA
EMERGENCY PANIC BUTTON OPERATED VIA REMOTE
The panic feature is activated by pressing the right button on the remote control
transmitter for 3 seconds. This sets off the siren. To cancel "panic", press the
right button on the transmitter for 1 second. NOTE: Panic does not work when
the ignition is on by requirement of Australian Law (EPA).
L
R
TO ARM/DISARM ALARM
The alarm is activated by pressing the RIGHT button on the remote control transmitter. The
blinkers will flash once, and the siren will beep once. The dash LED-light will stay on for 20
seconds then flash, THE ALARM IS NOW ON. To deactivate the alarm, press the RIGHT
button again. The blinkers will flash twice and the siren will beep twice. THE ALARM IS NOW
OFF.
For audible arm / disarm
use the RIGHT button.
For silent arm / disarm
hold BOTH buttons down for approximately 4 seconds.
PAT™ PAST ALARM TRIGGER MEMORY
If the alarm was triggered by an intruder while your alarm was set, it will beep the siren and
flash the blinkers four times on disarm. The system will also store the ten last times the alarm
has been activated in its memory, and can tell you what has triggered the system. Please refer
to "Features used by Installers/Servicemen" contained later in this instruction.
DOME LIGHT EXTENSION
The interior light will be automatically illuminated for 20 seconds when the driver disarms the
alarm. This allows the owner to verify that the vehicle is safe to enter plus giving the added
convenience of being able to see inside the vehicle even when the doors are closed. The interior
light will automatically turn off if the ignition is turned on, or if the alarm is armed again. This
feature is automatically disabled when passive arm and auto rearm are enabled.
DOOR AJAR WARNING FEATURE
If the vehicles doors are not properly closed when you try to activate your alarm system, the
blinkers will flash and the siren will continuously beep for 3 seconds to alert you that the
vehicle is not secure.

Advertisement

loading
Need help?

Need help?

Do you have a question about the RA96 and is the answer not in the manual?

Questions and answers

Summary of Contents for RHINO RA96

  • Page 1 OPERATION INSTRUCTIONS FOR ROLLING CODE ALARM: RA96 INSURANCE APPROVED SPLIT SYSTEM MODEL WITH ENGINE IMMOBILISATION AND BOOT RELEASE MADE IN AUSTRALIA EMERGENCY PANIC BUTTON OPERATED VIA REMOTE The panic feature is activated by pressing the right button on the remote control transmitter for 3 seconds.
  • Page 2 SELECTABLE PASSIVE ARM & RE-ARM FEATURE These two fetures as outlined below can be turned on only if desired by the owner. When the alarm initially has power connected to it, or when the system is turned off by the master switch on the back of the siren, these features will be turned off.
  • Page 3 C. Immediately press and hold the right button on the new remote control for at least 4 seconds. D. Turn the vehicles ignition off. E. The new remote control is now programmed into the alarm. RHINO ALARM MODEL: RA96 SYSTEM FEATURES ~ All Microprocessor Controlled ~ Rolling Code Technology (Anti-Scanning, Anti-Code Grabbing) ~ Two SSR™...
  • Page 4 ~ Impact Sensor and Ultrasonic Isolation Programmable via Remote Control ~ Electric Boot Release Output via Remote Control FEATURES USED BY INSTALLERS / SERVICEMEN 1. INSTALLER / SERVICE MODE: Service mode is accessed by turning the keyswitch to the off position. This enables complete deactivation of the system without using the remote control.
  • Page 5 I M P O R T A N T N O T E F O R I N S T A L L E R S V e h i c l e s f i t t e d w i t h n e g a t i v e o r p o s i t i v e s w i t c h i n g d o o r s .
  • Page 6: Wiring Instructions

    ALARM OVER RIDE. CONNECT TO THE WHITE WIRE ON AN SB41. CURRENT SENSING The alarm is fitted standard with current sensing. This feature incorporated in Rhino systems has been proven to be very reliable. The alarm will detect any sudden drop in voltage in the vehicle’s electrical system, for example if the interior light comes on, or if the electrical system...
  • Page 7: Alarm Wiring Diagram

    WARNING: If turbo cooling fans run after the ignition key is turned off, you then must connect the pink wire to the positive power feed wire of the electric cooling fan. This will override the fan from causing false alarms due to voltage drop. ALARM WIRING DIAGRAM 15A FUSE +12 VOLTS...
  • Page 8 IMPORTANT NOTE : Vehicles fitted with an interior light delay. Vehicles fitted with an interior light delay require a diode to be added to prevent the alarm giving a door ajar warning. Please follow the wiring diagram below : +12V Interior light DOOR DELAY CIRCUIT...
  • Page 9 CONNECT OPTIONAL RELAYS AS SHOWN LOCK (ORANGE/BLACK WIRE ON ALARM) 15A FUSE +12V (PINK YELLOW) UNLOCK LOCK OUTPUT UNLOCK OUTPUT FOR POSITIVE AT REST THEN GOING NEGATIVE “OR” NEGATIVE AT REST THEN GOING POSITIVE PUT 87’S TO +12V CONNECT OPTIONAL RELAYS AS SHOWN LOCK (ORANGE/BLACK WIRE ON ALARM) +12V +12V OR GROUND...