PARAMETER LIST
Parameter
Name
881
Speed feed forward gain
Regeneration avoidance
882
operation selection
Regeneration avoidance
883
operation level
Regeneration avoidance at
884
deceleration detection
sensitivity
Regeneration avoidance
885
compensation frequency
limit value
Regeneration avoidance
886
voltage gain
888
Free parameter 1
889
Free parameter 2
Cumulative power monitor
891
digit shifted times
892
Load factor
Energy saving monitor
893
reference (motor capacity)
Control selection during
894
commercial power-supply
operation
Power saving rate reference
895
value
896
Power unit cost
Power saving monitor
897
average time
Power saving cumulative
898
monitor clear
Operation time rate
899
(estimated value)
C0
FM terminal calibration
(900)
C1
AM terminal calibration
(901)
C2
Terminal 2 frequency setting
(902)
bias frequency
C3
Terminal 2 frequency setting
(902)
bias
125
Terminal 2 frequency setting
(903)
gain frequency
C4
Terminal 2 frequency setting
(903)
gain
C5
Terminal 4 frequency setting
(904)
bias frequency
C6
Terminal 4 frequency setting
(904)
bias
126
Terminal 4 frequency setting
(905)
gain frequency
C7
Terminal 4 frequency setting
(905)
gain
C8
Current output bias signal
(930)
C9
Current output bias current
(930)
C10
Current output gain signal
(931)
C11
Current output gain current
(931)
C12
Terminal 1 bias frequency
(917)
(speed)
C13
Terminal 1 bias (speed)
(917)
17
Setting
Initial
Range
Value
0%
0 to 1000%
0
0, 1, 2
760/
300 to 800V
785VDC
*2
0 to 5
0
0 to 10Hz,
6Hz
9999
0 to 200%
100%
9999
0 to 9999
9999
0 to 9999
9999
0 to 4, 9999
100%
30 to 150%
Inverter
0.1 to 55/
rated
0 to 3600kW
*2
capacity
0
0, 1, 2, 3
9999
0, 1, 9999
9999
0 to 500, 9999
0,1 to 1000h,
9999
9999
9999
0, 1, 10, 9999
0 to 100%,
9999
9999
0Hz
0 to 400Hz
0%
0 to 300%
Hz
0 to 400Hz
50
100%
0 to 300%
0Hz
0 to 400Hz
20%
0 to 300%
Hz
0 to 400Hz
50
100%
0 to 300%
0 to 100%
0%
0 to 100%
0%
0 to 100%
100%
0 to 100%
100%
0Hz
0 to 400Hz
0%
0 to 300%
Parameter
Name
C14
Terminal 1 gain frequency
(918)
(speed)
C15
Terminal 1 gain (speed)
(918)
C16
Terminal 1 bias command
(919)
(torque/magnetic flux)
C17
Terminal 1 bias (torque/
(919)
magnetic flux)
C18
Terminal 1 gain command
(920)
(torque/magnetic flux)
C19
Terminal 1 gain (torque/
(920)
magnetic flux)
C38
Terminal 4 bias command
(932)
(torque/magnetic flux)
C39
Terminal 4 bias (torque/
(932)
magnetic flux)
C40
Terminal 4 gain command
(933)
(torque/magnetic flux)
C41
Terminal 4 gain (torque/
(933)
magnetic flux)
Parameter copy alarm
989
release
990
PU buzzer control
991
PU contrast adjustment
Pr. CL
Parameter clear
ALLC
All parameter clear
Er.CL
Alarm history clear
PCPY
Parameter copy
*1
Differ according to capacities. (00023, 00038/00052 to 00126/00170,
00250/00310 to 01800/02160 or more)
*2
Differ according to capacities. (01800 or less/02160 or more)
*3
Differ according to capacities. (00250 or less/00310 or more)
*4
Differ according to capacities. (00250 or less/00310 to 01800/02160 or
more)
*5
Setting can be made only when the FR-A7AP is mounted.
Setting
Initial
Range
Value
Hz
0 to 400Hz
50
100%
0 to 300%
0%
0 to 400%
0 to 300%
0%
0 to 400%
150%
0 to 300%
100%
0 to 400%
0%
0 to 300%
20%
150%
0 to 400%
100%
0 to 300%
10/100
10/100
*2
0, 1
1
0 to 63
58
0, 1
0
0
0, 1
0
0, 1
0
0, 1, 2, 3