PARAMETER LIST
Parameter
Name
RUN terminal function
190
selection
SU terminal function
191
selection
IPF terminal function
192
selection
OL terminal function
193
selection
FU terminal function
194
selection
ABC1 terminal function
195
selection
ABC2 terminal function
196
selection
232 to
Multi-speed setting (8 speed
239
to 15 speed)
Soft-PWM operation
240
selection
Analog input display unit
241
switchover
Terminal 1 added
242
compensation amount
(terminal 2)
Terminal 1 added
243
compensation amount
(terminal 4)
Cooling fan operation
244
selection
245
Rated slip
Slip compensation time
246
constant
Constant-power range slip
247
compensation selection
250
Stop selection
Output phase failure
251
protection selection
252
Override bias
253
Override gain
255
Life alarm status display
Inrush current limit circuit
256
life display
Control circuit capacitor life
257
display
Main circuit capacitor life
258
display
Main circuit capacitor life
259
measuring
PWM frequency automatic
260
switchover
13
Setting
Initial
Parameter
Range
Value
0 to 8, 10 to
0
20, 25 to 28,
30 to 36, 39,
41 to 47, 64,
1
70, 84, 85, 90
to 99,
100 to 108,
2
110 to 116,
120, 125 to
128, 130 to
3
136, 139, 141
to 147, 164,
170, 184, 185,
4
190 to 199,
9999
0 to 8, 10 to
20, 25 to 28,
30 to 36, 39,
41 to 47, 64,
99
70, 84, 85, 90,
91, 94 to 99,
100 to 108,
110 to 116,
120, 125 to
128, 130 to
136, 139, 141
9999
to 147, 164,
170, 184, 185,
190, 191, 194
to 199, 9999
0 to 400Hz,
9999
9999
1
0, 1
0
0, 1
100%
0 to 100%
75%
0 to 100%
1
0, 1
9999
0 to 50%, 9999
0.5s
0.01 to 10s
9999
0, 9999
0 to 100s,1000
9999
to 1100s
8888, 9999
1
0, 1
50%
0 to 200%
0 to 200%
150%
0
(0 to 15)
(0 to 100%)
100%
100%
(0 to 100%)
100%
(0 to 100%)
0, 1
0
1
0, 1
Name
261
Power failure stop selection
Subtracted frequency at
262
deceleration start
Subtraction starting
263
frequency
Power-failure deceleration
264
time 1
Power-failure deceleration
265
time 2
Power failure deceleration
266
time switchover frequency
267
Terminal 4 input selection
Monitor decimal digits
268
selection
269
Parameter for manufacturer setting. Do not set.
Stop-on contact/load torque
270
high-speed frequency
control selection
High-speed setting
271
maximum current
Middle-speed setting
272
minimum current
273
Current averaging range
Current averaging filter time
274
constant
Stop-on contact excitation
275
current low-speed
multiplying factor
PWM carrier frequency at
276
stop-on contact
278
Brake opening frequency
279
Brake opening current
Brake opening current
280
detection time
281
Brake operation time at start
282
Brake operation frequency
283
Brake operation time at stop
Deceleration detection
284
function selection
Overspeed detection
frequency
285
(Excessive speed deviation
detection frequency)
286
Droop gain
287
Droop filter time constant
Droop function activation
288
selection
291
Pulse train I/O selection
Automatic acceleration/
292
deceleration
Acceleration/deceleration
293
separate selection
294
UV avoidance voltage gain
Rotation direction detection
299
selection at restarting
RS-485 communication
331
station number
RS-485 communication
332
speed
Setting
Initial
Range
Value
0
0, 1, 2, 11, 12
3Hz
0 to 20Hz
0 to 120Hz,
Hz
50
9999
5s
0 to 3600/360s
0 to 3600s/
9999
360s, 9999
0 to 400Hz
Hz
50
0
0, 1, 2
9999
0,1, 9999
0
0, 1, 2, 3
0 to 220%
50%
100%
0 to 220%
0 to 400Hz,
9999
9999
16
1 to 4000
0 to 1000%,
9999
9999
0 to 9, 9999/
9999
0 to 4, 9999
*2
3Hz
0 to 30Hz
130%
0 to 220%
0.3s
0 to 2s
0.3s
0 to 5s
0 to 30Hz
6Hz
0.3s
0 to 5s
0, 1
0
0 to 30Hz,
9999
9999
0%
0 to 100%
0.3s
0 to 1s
0
0, 1, 2, 10, 11
0, 1, 10, 11,
0
20, 21, 100
0, 1, 3, 5 to 8,
0
11
0
0 to 2
0 to 200%
100%
0
0, 1, 9999
0 to 31
0
(0 to 247)
3, 6, 12, 24,
48, 96, 192,
96
384