Installation - Firegear AF-1100 VALVE SERIES Installation And Operation Instructions Manual

Af-1100 valve series revolution unvented gas log heater & vented decorative gas log hearth kit – on / off remote
Table of Contents

Advertisement

CLEARANCES FOR VENTED APPLICATIONS
PROPER CLEARANCES FROM COMBUSTIBLE
CONSTRUCTION AND MATERIALS MUST BE
MAINTAINED FROM ALL SIDES, TOP, AND BOTTOM
OF THIS APPLIANCE.
THIS APPLIANCE SHOULD NEVER BE PLACED
NEAR ANY COMBUSTIBLE SURFACE.
THIS APPLIANCE SHOULD NEVER BE PLACED
UNDER ANY COMBUSTIBLE CONSTRUCTION OR
MATERIALS.
NEVER PLACE ANY COMBUSTIBLE MATERIAL
WITHIN TWENTY-FOUR ( 24" ) FROM THE FRONT
OF THE FIREPLACE ENCLOSURE.
FIGURE 9
!!! WARNING !!!
FOR VENTED APPLICATIONS: The damper clamp must be
installed in a manner, which will maintain the minimum
permanent damper vent opening at all times. SEE FIGURE 9.
See the Decorative Gas Log Set Specifications on page 3 & 4.
!!! WARNING !!!
The State of Massachusetts requires that the chimney flue
damper, when used with decorative gas log sets, be welded
open or completely removed. In the Commonwealth of
Massachusetts, this appliance must be installed by a licensed
plumber or gasfitter.
!!! WARNING !!!
FOR VENTED APPLICATIONS: This appliance, must be
installed only in a solid-fuel burning fireplace with a working
flue and constructed of noncombustible materials. This unit is
NOT for use with solid fuel. Solid fuels shall NOT be burned in
a fireplace where a decorative gas appliance is installed.

INSTALLATION

Installation will be much easier if two ( 2 ) or more people co-
operate in locating and installing the unit.
FOR VENTED APPLICATONS: This appliance must be
installed only in a solid-fuel burning fireplace, with a working
flue, and constructed of noncombustible materials.
!!! WARNING !!!
Gas supply system must be installed in accordance with the
U.S. National Fuel Gas Code.
This appliance and its individual shut off valve must be
disconnected from the gas supply piping system during any
system pressure test in excess of ½ PSI ( 3.5 KPA ).
Use a system manual shut off valve to shut off the gas supply
to this gas appliance before continuing with installation
procedures.
!!! IMPORTANT !!!
FOR VENT-FREE APPLICATIONS: If the appliance is to be
installed in a solid-fuel burning fireplace, have the fireplace and
chimney, professionally cleaned, to remove any ashes, soot,
creosote, or loose debris. The fire box must be sealed from
any potential drafts, from cleanouts, ill-fitting dampers, cracks,
etc...
!!! IMPORTANT !!!
FOR VENT-FREE APPLICATIONS: Seal any fresh air vents or
ash clean-out doors located on the floor or wall of the fireplace.
If this is not performed, drafting may cause pilot outage or
sooting. Use a heat-resistant sealant. SEAL THE DAMPER,
ONLY IN VENT-FREE APPLICATIONS!
!!! IMPORTANT !!!
FOR VENTED APPLICATIONS: Before installing this
appliance, have the fireplace and chimney, professionally
cleaned, to remove any ashes, soot, creosote, or other
obstructions. Perform this cleaning annually, after installation.
!!! IMPORTANT !!!
FOR VENTED APPLICATIONS: Seal any fresh air vents or
ash clean-out doors located on the floor or wall of the fireplace.
If the above conditions are not met, drafting may cause pilot
outage or sooting. Use a heat-resistant sealant; DO NOT seal
the chimney flue damper.
!!! IMPORTANT !!!
Decorative Gas Log Sets are shipped with the appropriate gas
connections for each type of gas, i.e., Natural Gas or Liquid
Propane. If you have purchased an inappropriate unit for your
application, contact your retailer, installer, or the firegear
Customer Service Center.
WARNING: This appliance is equipped for ( Natural or
Propane ) gas. Field conversion is not permitted.
7