Clearances - Firegear AF-1100 VALVE SERIES Installation And Operation Instructions Manual

Af-1100 valve series revolution unvented gas log heater & vented decorative gas log hearth kit – on / off remote
Table of Contents

Advertisement

MINIMUM FIREPLACE DIMENSIONS
MINIMUM FIREPLACE DIMENSIONS
FACTORY BUILT FIREPLACES
Chimney Height minimum of 10 feet – Vented Applications
LOG
FRONT
DEPTH
SET
WIDTH IN
SIZE
INCHES
INCHES
30"
FG-360A11
FG-420A11
36"
CLEARANCES FOR UNVENTED APPLICATIONS
PROPER CLEARANCES FROM COMBUSTIBLE
CONSTRUCTION AND MATERIALS MUST BE MAINTAINED
FROM ALL SIDES, TOP, AND BOTTOM OF THIS
APPLIANCE.
THIS APPLIANCE SHOULD NEVER BE PLACED NEAR
ANY COMBUSTIBLE SURFACE.
THIS APPLIANCE SHOULD NEVER BE PLACED UNDER
ANY COMBUSTIBLE CONSTRUCTION OR MATERIALS.
MINIMUM DIMENSIONS – SOLID-FUEL BURNING & UL 127
FACTORY BUILT FIREPLACES ( SEE FIGURE 1 )
LOG
REAR
DEPTH
SET
WIDTH IN
MODEL
INCHES
INCHES
A
21.5"
FG-360A11
26"
FG-420A11
FIGURE 1
The dimensions shown and defined in the fireplace
manufacturer's instructions, are the minimum clearances that
must be maintained, when installing this appliance.
Follow these instructions to insure safe installation. Failure to
follow these instructions exactly, can create a fire hazard.
continued
HEIGHT
MINIMUM
IN
IN
VENT IN
INCHES
SQ INCHES
14"
19"
16.6 sq. in.
14"
20"
22.1 sq. in.
FRONT
HEIGHT
IN
WIDTH IN
IN
INCHES
INCHES
B
C
D
14"
30"
19"
14"
36"
20"
SIDEWALL & CEILING CLEARANCES
The sides of the fireplace opening must be a minimum of six
( 6" ) inches from any combustible wall material.
The ceiling must be a minimum of forty-two ( 42" ) inches from
the fireplace opening. ( SEE FIGURE 2 )
MANTEL CLEARANCES WITHOUT HOOD
You must have non-combustible material above the fireplace
opening. Non-combustible material must extend a minimum of
twelve ( 12" ) inches above the fireplace opening.
using sheet metal, you must have non-combustible material
behind it. ( SEE FIGURE 3 )
Heat resistant materials, such as slate and marble, must be at
least ½" thick. Sheet metal should NOT be installed onto
combustible material. ( SEE FIGURE 3 )
!!! WARNING !!!
If you can not meet these minimum clearances, you MUST
operate this appliance with the chimney flue damper open, OR
you must use a hood. See instructions for vented operations.
Material Distance
12" or more
Less than 12"
4
FIGURE 2
When
Safe Installation
Non-combustible material
Non-combustible material must be
extended to at least 8" with the
installation of the optional fireplace
hood. If you can not extend non-
combustible material at least 8",
you must operate heater with the
chimney flue damper open.