Trouble Shooting - Firegear AF-1100 VALVE SERIES Installation And Operation Instructions Manual

Af-1100 valve series revolution unvented gas log heater & vented decorative gas log hearth kit – on / off remote
Table of Contents

Advertisement

FIREGEAR REVOLUTION VENTED / UNVENTED GAS LOG
PROBLEM OBSERVED
Gas odor during set up
Gas odor before first ignition
Pilot will not ignite, or will not stay lit
Delayed ignition
Burner does not light but pilot remains on
Burner lights but does not stay lit
while pilot remains on
Burner & pilot light but will not stay on
Incorrect burner flame
Backfire of burner
Appliance produces unwanted odors
Logs appear to smoke
Whistle noise from appliance
HEARTH KIT TROUBLE SHOOTING
POSSIBLE CAUSE
Gas leak
Gas leak
No gas to pilot
Thermocouple not hot
Improper pilot flame adjustment
Loose connections on thermocouple
Faulty pilot or thermocouple
Faulty Regulator
Faulty Valve
Low gas pressure
Clogged or dirty burner ports
Blocked orifice
Faulty Valve
Faulty Regulator
Low gas pressure
Clogged or dirty burner ports
Blocked orifice
Faulty pilot or thermocouple
Faulty Valve
Faulty Regulator
Low gas pressure
Faulty Valve
Faulty pilot or thermocouple
Clogged or dirty burner ports
Faulty Regulator
Low gas pressure
Not enough fresh air for ODS
Faulty Valve
Faulty pilot or thermocouple
Clogged or dirty burner ports
Faulty Regulator
Remote control overheating
Remote control batteries failing
Incorrect gas supply or pressure
Blocked orifice
Clogged or dirty burner ports
Faulty Valve
Faulty Regulator
High altitude
Blocked orifice
Clogged or dirty burner ports
Low gas pressure
Vapors from paint, hair spray, glues, etc
Initial burn off of manufacturing chemicals
Vapors from manufacturing chemicals
Logs curing
Air in gas line
Control knob not in fully open position
Spiral gas flex line
CORRECTIVE MEASURE
See " What to do if you smell gas " page 1
Check all gas connections
See " What to do if you smell gas " page 1
Check all gas connections
Make sure gas is on, in pilot position
Depress valve knob for at least 1 minute
See Pilot Characteristics - adjust flame
Check gas connections
Replace Safety Pilot
Replace Regulator
Replace Valve
Check gas supply pressure
Clean burner ports
Check orifice opening
Replace Valve
Replace Regulator
Check gas supply pressure
Clean burner ports
Check orifice opening
Replace Safety Pilot
Replace Valve
Replace Regulator
Check gas supply pressure
Replace Valve
Replace Safety Pilot
Clean burner ports
Replace Regulator
Check gas supply pressure
Open door or window - ventilate
Replace Valve
Replace Safety Pilot
Clean burner ports
Replace Regulator
Move away from flame
Replace batteries
Check gas supply pressure
Check orifice opening
Clean burner ports
Replace Valve
Replace Regulator
Adjust orifice size for altitude
Check orifice opening
Clean burner ports
Check gas supply pressure
Ventilate room
Ventilate room
Ventilate room
See curing of Refractory Logs
Bleed lines
Open control knob to full open
Replace gas feed line