OPERATION continued
!!! WARNING !!!
All gas burning appliances produce smoke and carbon
monoxide gas during operation. These fumes can be harmful
if the appliance is used in any other than a fully vented, or
certified vent-free fireplace.
!!! WARNING !!!
A fireplace screen must be in place when this appliance is in
operation. Unless other provisions for combustion air are
provided, the screen shall have an opening(s) for introduction
of combustion air.
!!! WARNING !!!
When this gas appliance is used in a fireplace equipped with a
combustion air kit and glass doors, the glass doors should
remain open during log set operation. This will maximize the
radiant heat provided to the surrounding area, and minimize
overheating of any valve installation. The glass doors may be
closed when the log set is not in use.
FIGURE 30
!!! WARNING !!!
WHEN OPERATING THIS VENT-FREE APPLIANCE: DO
NOT burn candles, oil lamps, incense, or any carbon producing
flame, as this will cause soot. Refrain from smoking, the use of
aerosols, hairspray, cleaning products, painting or staining,
etc..., as these will cause soot and unpleasant odors.
!!! WARNING !!!
WHEN OPERATING THIS VENT-FREE APPLIANCE: DO
NOT use ceiling fans, or oscillating floor fans, as these will
cause drafts, and unwanted air thermals, that will cause soot.
!!! WARNING !!!
DO NOT use this appliance as a sole source of heat; it is
intended as a supplemental heat source.

LIGHTING INSTRUCTIONS

1-
STOP! Read all warnings and safety information in this
manual.
LIGHTING THE PILOT
2-
Push in the gas control knob slightly, and turn it in a
clockwise direction to the OFF position. DO NOT FORCE!
NEVER USE ANY TOOL, TO ROTATE THE GAS
CONTROL KNOB! If gas control knob will not rotate,
contact your installer or the firegear Service Center.
( SEE FIGURE 30 & 31 )
3-
Slowly, turn on the gas, at the manual shut-off valve,
beside the fireplace.
4-
STOP! WAIT FIVE ( 5 ) MINUTES!
5-
If you smell gas, STOP!
6-
Turn off the gas at the manual shut-off valve, and recheck
all gas connections for leaks. Do not continue until all
leaks are corrected. Once you are assured that there are
no leaks, proceed with step seven ( 7 ).
7-
Locate the pilot; pilot is located at the rear, left-center, of
the burner. ( SEE FIGURE 27, 28, 29, & 32 )
8-
USING THE PIEZO FOR PILOT IGNITION: Depress the
gas control knob all the way down, and turn the knob in a
counter-clockwise direction, to the pilot position. Press the
piezo igniter button, until the pilot is lit. Continue to hold
the gas control knob down for approximately one ( 1 )
minute, after the pilot is lit.
9-
Pilot should remain lit, and control knob should pop back
out when released. If not, repeat the aforementioned
steps. If pilot ignition does not take place, contact your
installer or the firegear Service Center.
10- MANUAL PILOT IGNITION: While holding a burning,
long hearth match or hand fire starter, near the pilot head,
depress the gas control knob all the way down, and turn
the knob in a counter-clockwise direction, to the pilot
position. Continue to hold the gas control knob down for
approximately one ( 1 ) minute, after the pilot is lit.