Log Installation; Lighting And Shutdown - New Buck Corporation 60 Installation Manual

Gas-fired vented room heaters
Table of Contents

Advertisement

G)
COMPLETE THE INSTALLATION
1.
Position the logs, either Model 40, 60 or 25 as illustrated
below.
c
Model 60
Figure 5
2.
Replace the glass enclosure.
H)
LIGHTING AND SHUTDOWN
NOTE:
Prior to lighting, check all fittings for leakage.
This
is accomplished by applying soapy water on all connections made.
If there is any leakage bubbles will appear at the point of
connections.
If bubbles occur, tighten the fittings until the
bubbles no longer appear.
All connections made at the factory
have been previously tested.
NOTE:
The appliance and its' individual shut off valve must be
disconnected from the gas supply piping system during any pressure
testing of the system at test pressures in excess of 1/2 psig
(3.5 kPa) .
The appliance must be isolated from the gas supply piping system
by closing its individual manual shut off valve during any
pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psig (3. 5kPa) .
An 1/8" NPT plugged tap is located on the right side of regulator,
immediately upstream of the gas supply connection to the appliance.
This is used for test gauge connection.