MASONRY INSERT INSTALLATION
MANTEL AND
/oCt?
SUPPORlS
CC».1BUSllBLE PROJECllNG
MORE THAN 3/4"
INSERT TOP
C
MIN. SIDES
&
TOP
TO COMBUS1lBLE MA!ERIAL
Figure 8
IMPORTANT:
1.
Caution:
Read entire manual before installing unit.
2.
for clearance see Figure 8.
3.
Masonry inserts must be installed as follows:
A.
Model 40 masonry inserts must be installed on legs
long enough to leave at least 1" air space from outer
skin to bottom of fireplace.
B.
Model 60 masonry insert must be installed on
i"
material
provided with kit, to leave at least
i"
air space from
outer bottom to bottom of fireplace.
Trim panels may be
connected directly to side of unit.
C.
Model 25 may be installed in any masonry fireplace that
will accept its height.
Trim panels must be installed
BEHIND slots on outer skin.
4.
All units must be vented with 4" pipe from top of unit to
entire height of existing chimney.
5.
For masonry inserts your units must be equipped with manual
igniter.
See example B for light up and shut down instructions.
CAUTION:
Read 1 - 7, page 10 carefully before lighting your
unit for the first time.