Vision GA5100 Series User Manual page 5

1550nm erbium doped fiber amplifier
Table of Contents

Advertisement

Menu # 7 - TEC1
Read-only menu, tells the current of pump in cooling/heating
situation
Menu # 8 - TEC2
Read-only menu, tells the current of pump in cooling/heating
situation
Menu # 9 - PUMP TEMP1
Read-only menu, tells the temperature of pump
Menu # 10 - PUMP TEMP2
Read-only menu, tells the temperature of pump
Menu # 11 - +5V Reads
Read-only menu, displays the voltage +5V
Menu # 12 - -5V Reads
Read-only menu, displays the voltage -5V
Menu # 13 - UNIT TEMP
Read-only menu, tells the temperature of chassis
Menu # 14 - IP
Adjustable list, displays the IP address of SNMP
Menu # 15 - Sub
Adjustable list, display the address of net mask
Menu # 16 - GW
Adjustable list, displays the gateway address of SNMP
Menu # 17 - TR1
Adjustable list, displays the TRAP1 address of SNMP
Menu # 18 - TR2
Adjustable list, displays the TRAP2 address of SNMP
2.1.3
Menu assistant manual
1.
Input power (INPUT):
Input power >+10 dBm, display HIGHER;
Input power <-10 dBm, display LOWER.
2. Output (OUTPUT):
When input display HIGHER or LOWER, the output power displays
NO OUTPUT.
3. Laser temperature (TEMP): °C. The laser temp is seted in the
range of 20°C~30°C. If the detected temp exceeds the range, the
Page 3 of 7