1.4
Installation Requirements and
Recommendations
Before installing a Mobility Router, follow these requirements and recommendations.
1.4.1 Installation Location Guidelines
The Mobility Router should be installed in an environment sufficient for normal operation of
network appliances (50-95°F). Make sure that the area allows for enough ventilation after the
Mobility Router is installed. The appliance should be installed in an area that does not exceed
the following humidity range: 8-90% non-condensing.
1.4.2 Rack Requirements
The Mobility Router must be installed in a standard 19-inch rack. Make sure that the Mobility
Router is installed in the rack so that the Mobility Router is level in the rack and is fastened
by screws on both sides. Refer to
instructions.
1.4.3 Required Equipment for Installation
The following equipment is required for rack installation (and depends on the type of rack):
Mounting screws to rack mount the Mobility Router (not provided)
Screwdriver (not provided)
1.4.4 Uninterruptible Power Supply
We recommend installing the Mobility Router in an existing Uninterruptible Power Supply
(UPS) infrastructure.