CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing! FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START - UP! 1. Safety instructions Every person involved with installation and maintenance of this device have to: - be qualilfied - follow the instructions of this manual CAUTION!
2.Operating determinations This device is a moving-head for creating decorative effects and was designed for indoor use only. If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.
4. Installation 4.1Fitting the lamp DANGER ! Install the lamps with the device switched off only. Unplug from mains before ! To insert the lamp BA 250/2 SE open the lamp cover on the back of the projector head by loosening the 3 fastening screws marked X,Y,Z on the cover.
4.2 Lamp adjustment Screws "A","B","C" The lampholder is aligned at the factory. Due to differences between lamps, fine adjustment may improve light performance. Strike the lamp, cancel all effects, open the shutter and set the dimmer intensity onto 00 % and focus the light on a flat surface (wall) or use function “LAAd”...
4.7 Manual zoom The lens system can be configured in the range between 8° and 22° beam angles.To set the desired beam angle, open the front cover of the head by opening the fasteners,loose the adjusting screws on the fresnel lens unit and adjust the required beam angle.Tighten the adjusting screws and place back the front cover of the head.
4.7 Rigging the fixture DANGER TO LIFE! Please consider the respective national norms during the installation! The installation must only be carried out by an authorized dealer! The installation of the projector has to be built and constructed in a way that it can hold 0 times the weight for hour without any harming deformation.
Page 11
delivery) or screw the clamps directly to the 2 holes (5) in the base. For overhead use, always install a safety-rope that can hold at least 10 times the weight of the fixture. You must only use safety-ropes with screw-on carabines. Pull the safety-rope through the two apertures on the bottom of the base and over the trussing system etc.
Page 12
Fixation via a mounting plate 1. Screw 2 clamps (1) to the mounting plate (4) with M12 bolts and lock nuts through the holes in the mounting plate (4). 2. Insert the 4 quick-lock fasteners (3) into the holes on the bottom of the base and tighten fully clockwise. 3.
4.8 DMX-512 connection/connection between fixtures The fixture is equipped with 3-pin XLR sockets for DMX input and output. Only use a shielded twisted-pair cable designed for RS-485 and 3-pin XLR-plugs and connectors in order to connect the controller with the fixture or one fixture with another.
5.ClubWash 250 CT-DMX Protocol-version 1.0 Channel Channel Value Function Type of control 16bit 8bit 0-55 proportional Coarse control of pan movement Pan Fine 0-55 proportional Fine control of pan movement Tilt 0-55 proportional Coarse control of tilt movement Tilt fine 0-55 proportional Fine control of tilt movement...
6. Controller mode The fixtures are individually addressed on a data link and connected to the controller.The fixtures respond to the DMX signal from the controller. 6.1 DMX addressing The control panel on the front panel of the fixture allows you to assign the DMX fixture address, which is defined as the first channel from which the ClubWash 250 will respond to the controller.
7. Stand - alone mode The fixtures on a data link are not connected to the controller but can execute pre-set programs which can be different for every fixture.To set the program to be played,see the "Stand-alone setting" ( menu "St.AL."). "Stand-alone operation"...
Page 18
LAMP (On,Off) tESt Mod Pan (0-255) tilt (0-255) Go... Mod St.AL. Auto tESt PrG. PrG. PrG.3 PLAY tESt PrG. PrG. PrG.3 Edit PrG. PrG. PrG.3 St.0 St.99 Pan (0-255) S.tim.(0.1-25.5) (s) COPY rESE. SPEC. MAnu. Pan (Pan1,Pan2,Pan3) dimr (dim0...dim4,dimC) LA.Ad.
9. Control menu The control panel situated on the front panel of the base offers several features. You can simply set the DMX address,read the number of the lamp or unit hours, switch On and Off the lamp, run test, make a reset and also use many functions for setting fixture behaviour.
totL --- The function shows the total number of the operation hours with the lamp on since the ClubWash 50 has been fabricated. rSEt --- The function shows the number of the operation hours with the lamp on that the ClubWash 50 has been powered on since the counter was last reset.In order to reset this counter to 0 you have to hold [UP] and[DOWN ] and press the [ENTER].
En.Sn. --- Switching on/of the lamp light sensor.Select this function to switch the lamp light sensor on or off.The option"On" is for the standard operation. Important: The option"Off" is for "emergency operation" only if the lamp light sensor is defective and you will wait for a service intervertion! If the lamp light sensor is switched off and at switching the lamp on the electron- ics will still try to ignite the lamp until it shines (even when the lamp is damaged or absent), on this account some...
9.7 Stand-alone setting Use this menu to set options for stand-alone mode as a selection of the playing program,programming and modifying current programs. Auto --- Presetting playback.This function allows you to select the program which will be played in the stand- alone mode after switching the fixture on.Selected program will be played continuously in a loop.
Page 23
9.9 Special functions Use this menu for special services like adjusting lamp or adjusting effects. MAnu. --- Manual control of the effects..Select this menu to call up presetted positions of the channel ef- fects. LA.Ad. --- Lamp adjustment.This function can be used when you make the fine adjustment of the lamp.If you select this function,all effects will be canceled,shutter will be opened and the dimmer intensity will be set onto 00%.By using the options "PAn, tilt,"...
10. Error and information messages HEAt This message appears if you try to switch on the lamp within 5 minutes after having switched it off (the lamp is too hot). The message will appear on the display if the lamp doesn't ignite within 28 seconds. The ClubWash 250 will store this information and automatically ignite the lamp when the 5 minutes period has expired.
11. Technical specifications Power supply: EU-model: Voltage:......208/230/240V AC, 50/60Hz ~ Fuse:.......T 3.15 A@230V US-model: Voltage:......100/120/208/230/240V AC, 50/60Hz ~ Fuse:........T 6.3 A@120V Power consumption:..410 VA Lamp: Sylvania BA 250/2 SE Optical System: High luminous-efficiency parabolic reflector -Fresnel lens of diameter 50 mm -Manualy adjustable beam angle from 8°...
Page 26
Rigging -Stands directly on the floor -Mounts horizontally or vertically with Omega brackets - truss orientation -Safety chain/cord attachment point Temperatures -Maximum ambient temperature : 45° C -Maximum housing temperature : 80° C Minimum distances -Min.distance from flammable surfaces: 0.5m -Min.distance to lighted object: .3m Weight (net): EU version:0.3 kg...
Beampath: 12. Maintenance and cleaning It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build up on or within the fixture. Otherwise, the fixture‘s light-output will be significantly reduced. Regular cleaning will not only ensure the maximum light-output, but will also allow the fixture to function reliably throughout its life.