Specifications (Technical Data) - Bosch 940 ES Installation Manual

Temperature modulated with electronic ignition
Hide thumbs Also See for 940 ES:
Table of Contents

Advertisement

• Failure codes for easy diagnostics and repair
• Easily removable one-piece cover
• Built in freeze prevention.
Note: The freeze prevention kit is designed to provide
protection for the water heater down to approximately
5°F for short term conditions only. It will not protect the
appliance in areas where the temperature is routinely
expected to be below freezing.
- The freeze prevention kit will not protect plumbing out-
side the appliance from freezing. Precautions should be
taken.
Accessories (Bosch part #)
• Optional wireless remote control accessory to
operate with the appliance (TSTAT2)
• Cascading kit (77090003962)
• Outdoor kit (BTOK)
• External water filter (8703305356)
• Gas conversion kit (8719002176)
• Vertical vent kit (ESVVT)
• Concentric vent /air intake kit (ESHCK)
• Horizontal vent kit (4TWHVK3SII)
• Stainless steel bird screen (L2594)
(fits into a 3" PCV fitting - Intake vent).
• Pipe Cover (PTPCES)
• High temperature kit (7736500074)
• Recess box kit (7736500043)
• Pressure relief valve (FWL-2).
BOSCH is constantly improving its
i
products, therefore specifications are
subject to change without prior notice.
1) 4TWHVK3S vent kit is compatible with this appliance
but requires the purchase of an additional 12" piece of
straight pipe to meet minimum vent length requirements.
The aluminum flex piping included with this kit is not
permissible for use with this appliance.
6 720 644 930
2.2
Approved in US/Canada
Capacity
Maximum flow rate: 7.15 GPM (27 l/min) at a 45°F
(25°C) rise.
Maximum output
160,500 Btu/h (47.0 kW)
Maximum input
199,000 Btu/h (58.3 kW)
Efficiency in %
Thermal efficiency > 82%
Min. Input
19,900 Btu/h (5.8 kW)
Temperature Control
Selection range: 100°F (38°C) - 140°F (60°C)
Default temperature: 122°F (50°C)
Stability: +/- 2°F (+/- 1°C)
1)
Gas Requirement
Gas connection (inches) - ¾"
Inlet gas pressure under operation (with a high hot
water flow rate)*
• Propane: 8" - 13" water column.
• Natural Gas: 3.5" - 10.5" water column.
* To measure gas pressure, see Measuring Gas
Pressure, chapter 3.14, page 33.
Water
• Hot water connection (inches) - ¾"
• Cold water connection (inches) - ¾"
• Water valve material: Polymer (PPS) (Polypropylene
• Minimum water flow: 0.5 gallon/minute (1,9 l/m).
• Minimum recommended water pressure: 30 PSI
• Minimum well pressure 40 psi, see page 29.
• Connections:
Combustion
• Design is NOx compliant with SCAQMD require-
• CO  250 ppm (measured)
• CO

Specifications (Technical data)

Sulfid)
Note: Activation varies with inlet water temperatures
from 0.5 - 1.6 gallon/minute (1,9 - 6.1 l/m).
(2.07 bar).
– Bottom of heater
ments - rule 1146,2 approved type 1 appliances
level set from factory, see chapter 6.4, page 40.
2
Appliance details
.
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

830 es

Table of Contents