Installation instructions
10' MIN.
2' MIN.
3' MIN.
FIRESTOP SUPPORT
FIRESTOP SUPPORT
HOSE
CLAMP
ELBOW
CONDENSATE
DRAIN
APPLIANCE
Fig. 17 Vertical venting installation (single pipe pene-
tration)
Warning: Single pipe penetration should be used
in non-freezing climates only!
Fig. 18 Vertical venting installation (twin pipe penetra-
tion)
16
RAIN CAP
STORM COLLAR
FLASHING
4" MIN.
AIR SPACE
6720608158-91.2Av
10' MIN.
2' MIN.
3' MIN.
CHIMNEY
MAY BE INSULATED
IF NECESSARY
HORIZONTAL RUN
1/4" RISE/FT
HANGER STRAP
ELBOW
HOSE
CLAMP
CONDENSATE
DRAIN
APPLIANCE
Fig. 19 Vertical venting installation - Masonry Chim-
ney (combustion air piping not shown)
3.3.4
Vent connections
B Attach the flue gas exhaust accessory (8 705 504
151) to the top of the unit (position 1) using the 4
screws and gasket provided. Fully insert stainless
steel vent pipe 1.5" minimum into the accessory and
tighten the clamp (position 2).
If using the 4" vent, a 3" to 4" increaser is
i
required immediately off the top of the
heater.
NOTE: Vent pipe must be completely ver-
i
tical when inserting or gasket inside ex-
haust accessory can become displaced.
Exhaust accessory can be removed with
vent pipe attached to check gasket posi-
tion.
RAIN CAP
STORM COLLAR
FLASHING
SILICONE SEAL
MORTAR
ELBOW
6720608158-14.2AL
6 720 644 930