Technical Data & Declaration Of Performance - Fireline PUREVISION Installation And Operating Instructions Manual

Freestanding stove range 5kw, 5kw wide & 8.5kw nominal outputs
Table of Contents

Advertisement

6.0 Technical Data & Declaration of Performance (DoP)
Manufacturer: Fireline UK Ltd, a Division of Charlton & Jenrick Ltd.
Range Designation: Purevision freestanding stoves.
Models: Purevision 5kW, 5kW Wide and 8.5kW with nominal outputs of 5kW, 5kW and 8.5kW.
Intended Use: Domestic heating appliances
Independently Performance & Safety tested by: Kiwa Gastec, Notified Body No: 0558
Constancy of Performance System: ISO9001
Model
Appliance weight (packed/unpacked) (Kg):
Approximate Output Range: (kW)
Harmonised EN European Standard (hEN):
Additional Characteristics Test Standard:
Additional Particulate Emission Test Standard:
Declared nominal output: (kW)
Tested nominal Output: (kW)
Tested wood re-fuelling interval: (h)
Flue gas mass flow: (g/s)
Mean CO emission (@13% O
Mean C
H
emission (@13% O
n
m
Mean NOx emission (@13% O
DIN+ particulates (@13% O
PD6434 Particulate Emissions High output: (gh
PD6434 Particulate Emissions Low output: (gh
Optical Density Time > 0.2 High (Mins)
Optical Density Time > 0.2 Low (Mins)
*Mean Flue Temperature: (Deg C)
Approximate Max Log Length: (mm)
Performance Characteristics on Ancit Briquetted Smokeless Fuel
Declared nominal output: (kW)
Tested nominal output: (kW)
Tested re-fuelling interval: (h)
Flue gas mass flow: (g/s)
Mean CO emission (@13% O
Mean Flue Temperature: (Deg C)
Signed:
NOTE: Refuelling intervals for testing are chosen according to the standards concerned for performance testing
and are comparative only. They do not relate directly to re-fuelling intervals that can be achieved on an installed
product. Re-fuelling intervals of 1-1.5h for wood and 3-4+ hours for Ancit would be more usual. Under normal
conditions on a low air control setting stoves should stay in overnight on suitable briquetted smokeless fuel.
Performance Characteristics on Wood Fuel
Test Report Issue Date:
Total Efficiency: (%)
3
) : (%) (Nmg/m
)
2
3
): (Nmg/m
)
2
3
): (Nmg/m
)
2
3
): (Nmg/m
)
2
-1
)
-1
)
Total Efficiency: (%):
3
) : (%) (Nmg/m
)
2
Safety Distances From Combustibles
Side Wall: (mm)
Rear Wall: (mm)
Peter Mintoft
October 2013
10
Purevision
Purevision
5kW
5kW Wide
105/94
120/108
3.1 - 6
3.8 - 8
EN13240:
EN13240:
2001 Amd 2:
2001 Amd 2:
2004
2004
DIN +
DIN +
PD6434
PD6434
10/2013
10/2013
80.2
82.2
5
5
4.9
5
0.75
0.76
3.6
3.6
0.1 (1250)
0.08 (1000)
96
61
124
128
17
10
2.5
3.2
1.5
1.5
1.2
0.2
0.7
0.4
301
274
300
400
74.8
80.0
5.0
5.0
5.0
5.0
1.01
1.07
3.7
2.7
0.16 (2000)
0.51 (6375)
239
174
400
250
600
450
Director
Purevision
Notes
8.5kW
153/139
4.9-10
EN13240:
2001 Amd 2:
2004
DIN +
PD6434
10/2013
76.7
8.5
8.4
0.75
5.9
0.1 (1250)
76
96
19
3.7
1.7
0.4
1.4
363
400 - 650
77.4
8.5
8.7
1.03
6.1
0.07 (875)
339
150
400
Purevision Freestanding
Issue 02 01/14

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents