10
REFIllINg thE SoFtENER WIth Salt
dE
gB
F
Nl
11
FRoSt pREVENtIoN
12
MaINtENaNcE
16
only for machines with optional built-in softener.
– When the Salt required
Æ
filled with regeneration salt.
– Wait until the wash program is finished.
– Open the door.
– Unscrew the softener lid and fill the softener with 2 kg of "Granular
regeneration salt" (do not use salt tablets).
clean seal and rim of softener lid carefully, before closing the lid.
– Close lid and tighten.
The Salt required indicator
In case of frost or longer operation pauses (e.g. for seasonal operations),
the machine must be completely drained.
This should be carried out by after sales service.
– Machines with exhaust heat recovery: Drain both fill hoses and
condenser (optionally, use compressed-air to empty).
Reset for operation:
– Open the door, push Program button
simultaneously until "boF" appears at the temperature indicator
Rinse
Å
.
– Push Start button
Á
("- - 1" appears at the temperature indicator
Wash
Ä
) and hold until water comes out of the booster overflow.
– Close the door.
The machine switches off and is now ready for operation.
For trouble-free operation, we recommend you enter into a service
contract with your local Service Office.
indicator illuminates, the softener has to be
Æ
goes off with delay.
Ã
and Drain button
Â
AG-21213-F-09-09