MAINTENANCE
Daily Inspection (Every 10 Hours)
¡ When the oil temperature is about 50 to
80°C (122 to 176°F):
The level should be near the upper limit
(H).
Replenishing
4
5
7
1. Remove cap nut (2).
2. Press button (3) and bleed the air from
the tank.
3. Tighten securely by hand with cap nut (2).
4. Remove the plug (10).
5. Supply hydraulic oil up to the middle of
the sight gauge (6).
6. Tighten the plug (10).
2
10
3
8
1
9
6
L3G008