SAE-400™
Read this entire installation section before you start installa-
tion.

SAFETY PRECAUTIONS

Do not attempt to use this equipment until you have thor-
oughly read all operating and maintenance manuals sup-
plied with your machine. They include important safety pre-
cautions, detailed engine starting, operating and mainte-
nance instructions and parts lists.
ELECTRIC SHOCK can kill.
•Do not touch electrically live parts such as
output terminals or internal wiring.
•Insulate yourself from the work and ground.
•Always wear dry insulating gloves.
------------------------------------------------------------------
ENGINE EXHAUST can kill.
•Use in open, well ventilated areas or vent
exhaust outside
•Do not stack anything near the engine.
------------------------------------------------------------------
MOVING PARTS can injure.
•Do not operate with doors open or guards
off.
•Stop engine before servicing.
•Keep away from moving parts
------------------------------------------------------------------
Only qualified personnel should install, use or service this
equipment

LOCATION/VENTILATION

The welder should be located to provide an unrestricted flow of clean,
cool air to the cooling air inlets and to avoid restricting the cooling air
outlets. Also, locate the welder so that the engine exhaust fumes are
properly vented to an outside area.
WARNING
DO NOT MOUNT OVER COMBUSTIBLE SURFACES
Where there is a combustible surface directly under station-
ary or fixed electrical equipment, that surface should be cov-
ered with a steel plate at least .06"(1.6mm) thick, which
should extend not less than 5.90(150mm) beyond the equip-
ment on all sides.
------------------------------------------------------------------

STACKING

These machines cannot be stacked.

ANGLE OF OPERATION

To achieve optimum engine performance the machine should be
run in a level position. The maximum angle of operation for the
Perkins engine is 30 degrees in all directions. If the engine is to be
operated at an angle, provisions must be made for checking and
maintaining the oil level at the normal (FULL) oil capacity in the
engine crankcase. When operating the welder at an angle, the
effective fuel capacity will be slightly less than the specified 22.5
gallons.

LIFTING

The equipment lift bail should be used to lift the machine.
• Lift only with equipment of adequate lifting
capacity.
• Be sure machine is stable when lifting.
• Do not lift this machine using lift bail if it is equipped with a
heavy accessory such as a trailer or gas cylinder.
FALLING
• Do not lift machine if lift bail is
EQUIPMENT can damaged.
cause injury.
• Do not operate machine while
suspended from lift bail.
------------------------------------------------------------------
A-2