INSTALLATION INSTRUCTIONS

MAINTENANCE

WARNING: SERVICING SHOULD BE CARRIED OUT ONLY BY AUTHORISED
PERSONNEL
During the guarantee period, in case of need all service intervention should be referred
back to the Service Department. Please note that intervention or repair by any
unauthorised personnel will invalidate such guarantee,
Before carrying out any maintenance, disconnect the appliance from the gas and electricity
supplies.
If a gas tap becomes stiff to operate, proceed as follows:
Remove the control knobs, pan supports, burners and hob fixing screws & clamps.
Remove the Hob from the worktop and remove any underside protective covers.
Disconnect the fixings holding the tap to the fascia panel, separate the assembly, then clean
the cone and seating with a cloth dampened with solvent.
Lightly smear the cone with high temperature grease, reassemble into position and rotate a
few times. Remove the cone again and remove any excess grease making sure that the gas
ducts are not obstructed with grease.
Carefully reassemble the components and check for gas soundness.
If it becomes necessary to replace the gas tap, proceed as follows:
Disconnect the appliance as described above.
Disconnect the gas pipe from the gas tap, disassemble from the gas rail by removing the
fixing screws.
When fitting a new tap, ensure that a new gasket is used.
Re-connect the gas tap, check for gas soundness and reassemble the hob.

ELECTRICAL DETAILS

Rated Voltage
Supply Connection
Power Input
Mains supply lead

GAS DETAILS

Connection
Type

TECHNICAL DATA

230V ac 50Hz
10 Amp GPO
0.008 to 0.02kW (depending on model)
3 x 0.75mm2 Type RR-F HAR marked
½" BSP
Natural Gas 1.0 kPa – alternative LPG 2.75 kPa
13