13. CONTROLLER BOARD [Auxiliary code V-2 and later]
[a] CONTROLLER BOARD LAYOUT
OUTPUT
Power Relay
(Synchronous Motor-2)
Illuminates (energized)
Flashes (bin full)
OUTPUT
Motor
Valve
Not used
INPUT
Micro Switch
Thermistor
[b] CHECKING CONTROLLER BOARD
* While checking the controller board for proper operation, keep all the connectors in
place, including those in the control box.
* If the ice making switch needs to be pressed to manually end a freeze cycle, wait for
at least 3 minutes after the freeze cycle begins (agitating motor starts). Otherwise, the
compressor will stop for 5 minutes (considered as low water condition).
* When the unit is unplugged, wait for 5 minutes before restarting the unit.
Not used
Not used
Power Transformer (Transformer-1)
Not used
54
Power Relay
(Compressor)
Hot Gas
Solenoid Valve
Fan Motor
Tilting Motor
(Synchronous Motor-1)
Agitating Motor
(Synchronous Motor-2)
Water Solenoid Valve
Not used
Not used
Not used