4-16 [F12] : End Setting

(Destination setting, USB ID write, Product mode setting)
1. The End setting consist of the following settings.
* Destination setting
* USB ID write
* Product mode setting (mass storage identification)
2. The setting must always be run when the adjustment software is terminated. Failure to run Terminal Setting will prevent
identification as Mass Storage when the camera is connected to the PC.
3. USB ID write details
1) USB ID write requires that the USB device (in this case FinePix A400) be unique throughout the world. For this reason,
each device has a unique ID as determined by the USB standard. If multiple devices with the same USB ID are connected
to a single PC, the PC will be unable to identify each USB device, thus preventing operation.
Item
Repair Date
Administrator ID
Repair Station
Repair Serial No.
Date information is acquired from the PC and written.
01(01)
U.S.A.
61(a)
CANADA
62(b)
HAWAII
63(c)
TAIWAN
64(d)
ENGLAND
66(f)
GERMANY
67(g)
FRANCE
68(h)
SPAIN
69(i)
ITALY
6A(j)
NETHERLANDS 6B(k)
BELGIUM
6C(l)
SWEDEN
6D(m)
SWITZERLAND 6E(n)
NORWAY
6F(o)
FINLAND
70(p)
SINGAPORE
71(q)
CHINA
74(t)
OTHER
7A(z)
A serial No. is assigned automatically and written
4. Adjustments
Details
SAPPORO
30(0)
SENDAI
31(1)
TOKYO
33(3)
NAGOYA
34(4)
OSAKA
35(5)
HIROSHIMA
37(7)
FUKUOKA
38(8)
69