Recommended Fuses, Circuit Breakers And Wire Sizes - ABB MicroFlex e150 User Manual

Servo drive
Hide thumbs Also See for MicroFlex e150:
Table of Contents

Advertisement

136 Technical data

Recommended fuses, circuit breakers and wire sizes

The following table describes the recommended fuses and circuit breakers for AC
power connections, and suitable wires sizes for AC and motor power connections.
Drive
Cont.
catalog
output
number
amps
(RMS)
E152A03..
3 A
E152A06..
6 A
E152A09..
9 A
Note: All wire sizes are based on 75 °C (167 °F) copper wire. Higher temperature
smaller gauge wire can be used per National Electric Code (NEC) and local codes.
Recommended fuses are based on 25 °C (77 °F) ambient, maximum continuous
control output current and no harmonic current. Earth/ground wires must be the same
gauge, or larger, than the L1, L2 and L3 wires.
AC
Input fuse
supply
type
Ferraz Shawmut:
6x32 FA series, 10 A
(W084314P)
BS88 2.5 URGS 10 A
(N076648J)
Ferraz Shawmut:
6x32 FA series, 8 A
(V084313P)
BS88 2.5 URGS, 7 A
(M076647J)
Ferraz Shawmut:
6x32 FA series, 20 A
(A084318P)
BS88 2.5 URGS, 20 A
(L097507J)
Ferraz Shawmut:
6x32 FA series, 12.5 A
(X084315P)
BS88 2.5 URGS, 12 A
(P076649J)
Ferraz Shawmut:
BS88 2.5 URGS, 25 A
(R076651J)
Ferraz Shawmut:
6x32 FA series, 20 A
(A084318P)
BS88 2.5 URGS, 20 A
(L097507J)
Circuit
breaker
(C-type)
or
or
or
12.5 A
or
or
Minimum
wire gauge
AWG
mm
10 A
14
2.0
8 A
14
2.0
20 A
14
2.0
14
2.0
25 A
14
2.5
20 A
14
2.0
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents