4 STAGE PAK
3. Mix color MODE
DIP10:ON
DIP9:ON
DIP8:OFF
DIP1-DIP7:mix color speed
4. RGB Manual Mode
DIP10:ON
DIP9:ON
DIP8:ON
DIP7:OFF
DIP1-DIP6:see figure below
DIP1
DIP2
R
DIP3
OFF
OFF
OFF
OFF
ON
OFF
33%
ON
OFF
ON
66%
OFF
ON
ON
100% ON
5

Operation Instructions

DIP4
G
DIP5
DIP6
OFF
OFF
OFF
OFF
OFF
33%
ON
OFF
ON
66%
OFF
ON
ON
100% ON
ON
4 STAGE PAK
Power Supply: The American DJ
ballast, which will auto sense the voltage when it is plugged into the power
source. With the electronic ballast you do not need to worry about wall volta-
ge, this unit can be plugged in anywhere.
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used
by most lighting and controller manufactures as a form of communication
between intelligent fixtures and controllers. A DMX controller sends DMX data
instructions from the controller to the fixture. DMX data is sent as serial data
that travels from fixture to fixture via the DATA "IN" and DATA "OUT" XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA "OUT"
terminal).
DMX Linking: DMX is a language allowing all makes and models of different
manufactures to be linked together and operate from a single controller, as
long as all fixtures and the controller are DMX compliant. To ensure proper
DMX data transmission, when using several DMX fixtures try to use the shor-
test cable path possible. The order in which fixtures are connected in a DMX
line does not influence the DMX addressing. For example; a fixture assigned
a DMX address of 1 may be placed anywhere in a DMX line, at the beginning,
at the end, or anywhere in the middle. Therefore, the first fixture controlled by
the controller could be the last fixture in the chain. When a fixture is assigned
a DMX address of 1, the DMX controller knows to send DATA assigned to
address 1 to that unit, no matter where it is located in the DMX chain.
B
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Ope-
OFF
ration): The 4 STAGE PAK can be controlled via DMX-
33%
512 protocol. The 4 STAGE PAK can be either a 8 or 10
66%
channel DMX unit. The DMX address is set electronically
using the controls on the front panel of the unit. Your unit
100%
and your DMX controller require an approved DMX-512
110 Ohm Data cable for data input and data output (Figure
1). We recommend Accu-Cable DMX cables. If you are
making your own cables, be sure to use standard 110-120 Ohm shielded
cable (This cable may be purchased at almost all pro lighting stores). Your
cables should be made with a male and female XLR connector on either end
of the cable. Also remember that DMX cable must be daisy chained and can-
not be split.

DMX Set Up

4 STAGE PAK contains a electronic
®
6