LG LAC6700R Service Manual page 18

Car cd/mp3/wma receiver
Hide thumbs Also See for LAC6700R:
Table of Contents

Advertisement

2-2. PIN FUNCTION (Note1)
Pin No.
Pin name
1
GND
Ground
2
FREG_B
External Trs bass drive (Note4)
3
FREG_F
FREG feedback terminal
4
ILMOUT
8.4V output for JLM/500mAmax
5
CTL4
FREG control terminal
6
CDOUT
8.0V output for CD/1.3Amax (Note4)
7
DSPOUT
3.3V output for DSP/250mAmax (Note4)
8
VB
Battery
9
CTL3
ILM control terminal
10
AUDIOOUT
8.4V output for AUDIO/500mAmax (Note4)
11
CTL1
DSP, CD, Audio control terminal
12
EXTOUT
High side output/600mAmax (Note4)
13
CTL2
EXT control terminal
14
VDDOUT
5.7V output for micro controller (Note4)
15
VBUP
Back up
Note1. In the uper table. "On" means always On. "Off" means compulsory Off and "On/Off" means that it can control by control
terminal.
Note2. Thermal protection circuit
A built-in thermal protection circuit (TSD:Thermal shut down) prevents thermal damage to the IC. All outputs except
VDD(pin14) and FREG (pin2&3) are switched off when the circuit operates, revert to the original state when the
temperature drops to a certain level.
Note3. Overvoltage protection circuit
The overvoltage protection circuit (surge protector) turns off all outputs without Vdd, when VB voltage is more than
about 21V. And the overvoltage protection circuit (surge protector) turns off Vdd output with other all outputs, when
VB voltage is more than about 26V. When the overvoltage protection operates on VB>=18V condition, the stand by
current increases.
Note 4. Overcurrent protection circuit
FREG_B (pin2), ILMOUT (pin4), CDOUT (pin6), DSPOUT (pin7), AUDIOOUT (pin10), EXITOUT (pin12), VDDOUT
(pin14) output circuits are built-in overcurrent protection circuit based on the respective output current. These
overcurrent protection circuits limit the current with a curve shape of "7" in the voltage-current graph. This prevents IC
destruction due to overcurrent.
Copyright © 2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Function
2-13
Protection function
Normal
(Note2)
operation
TSD On
-
-
On/Off
On/Off
On/Off
On/Off
On/Off
Off
-
-
On/Off
Off
On/Off
Off
-
-
-
-
On/Off
Off
-
-
On/Off
Off
-
-
On
On
-
-
(Note3)
(Note3)
VB=24V
VB=50V
-
-
Off
Off
Off
Off
Off
Off
-
-
Off
Off
Off
Off
-
-
-
-
Off
Off
-
-
Off
Off
-
-
On
Off
-
-
LGE Internal Use Only

Advertisement

Table of Contents
loading

Table of Contents