6 RECORDING
6-6 Series Recording
5
When the first VCR ends recording, the second VCR
starts recording automatically, then the third and so on.
• When the tape end output is set, series recording
signals are output from the [SERIES REC OUT]
terminal at the specified tape reel counter value,
signaling the next VCR to start recording.
The first VCR continues recording until the tape ends.
Non-stop continuous series recording
The series recording function allows you to record indefinitely using two VCRs. Recording alternates between each VCR.
To use this function, connect and set the VCRs as follows.
5
Connection
• Connect the [SERIES REC OUT] terminal of the
first VCR to the [SERIES REC IN] terminal of the
second VCR, and the [SERIES REC OUT]
terminal of the second VCR to the [SERIES REC
IN] terminal of the first VCR. The [COM]
terminals of both VCRs should be connected.
COM
CLOCK
COM
CLOCK
SERIES
SERIES
RESET IN
RESET IN
REC IN
REC IN
WARNING
CLOCK
SERIES
WARNING
CLOCK
SERIES
OUT
RESET OUT
REC OUT
OUT
RESET OUT
REC OUT
Second VCR
First VCR
• Connect audio and video terminals as shown in
the connection diagram on page 41.
42
If the <AUTO REW> menu switch in <VTR MODE> is
set to "OFF", the Stop mode is engaged when the end
of the tape is reached during recording. If <AUTO
REW> is set to "ON", the tape rewinds to the
beginning and stops.
• Counter value
When the tape is rewound to the beginning in the
Repeat Recording or Auto Rewind mode using the
counter end output function, the tape reel counter
value is reset to "0000".
5
Setting
• Set the <SRI/EXT REC> menu switch on both
units to "SERIES".
• Set the <AUTO REW> menu switch in <VTR
MODE> to "ON".
• Set the <AUTO REC CHECK> and <REPEAT
REC> menu switch in <VTR MODE> to "OFF".
5 For uninterrupted endless series recording, use the
counter end output function together. Set <CNT
TAPE END> so that the counter end signal is
output just before the tape end.
• Set <CNT TAPE END> in the <SRI/EXT MODE>
menu to "5500" (when a T-120 tape is used).
* When the tape is rewound to the beginning in
the Auto Rewind mode using the counter end
output function, the tape reel counter is reset
automatically to "0000".
Note:
• Continuous series recording over a long period
may produce excessive wear and tear on the
tapes and VCRs. Be sure to replace the tapes
periodically (refer to page 28).
6 RECORDING

6-7 Repeat Recording

When the tape comes to the end during recording, it is automatically rewound and recording starts again from the beginning.
5
To execute repeat recording, set <REPEAT REC> in
<VTR MODE> to "ON".
• The [REPEAT] indication in the VCR's display lights.
5
Setting the <TAPE END MODE> menu switch in
<ALARM/SENSOR MODE>
• If this menu switch is set to "STOP", the Stop mode is
forcibly engaged when the tape ends even if there is
an alarm or sensor recording.
To continue repeat recording even if an alarm
recording or sensor recording takes place during
recording, set <TAPE END MODE> to "OFF".
When the Tape End Forced Stop mode and Repeat
Rec mode are engaged and an alarm or sensor
recording takes place, the [REPEAT] indication goes
out.
5
Automatic recording check function
This unit is provided with an automatic recording
check function which automatically determines
whether or not recording is satisfactory at the tape
beginning in repeat recording.
• To activate the automatic recording check
function, set the <AUTO REC CHECK> menu
switch in <VTR MODE> to "ON".
5 Operation of the automatic recording check
function
• Recording is performed from the beginning of the
tape for several seconds during repeat recording.
Then the recorded section is automatically played
back to check whether or not the signals have
been recorded properly. If the recording is
satisfactory, recording resumes.
• If the recording is unsatisfactory, the heads are
cleaned automatically. Recording is restarted for
several seconds and then the recording is
checked again. If the recording is still
unsatisfactory, the error code "E-09" is shown on
the display and recording resumes.
Note:
• Continuous repeat recording over long periods
may produce excessive wear and tear on the
tape and VCR. Be sure to replace the tape
periodically (refer to page 28).
VIDEO/VTR MODE screen
*
*
*
*
*
*
[
V
I
D
E
O
*
M
O
D
E
]
*
*
*
*
*
*
1
.
I
N
P
U
T
*
*
*
*
*
*
*
*
*
*
*
*
*
L
I
N
E
2
.
D
E
T
A
I
L
*
*
*
*
*
*
*
*
*
*
*
*
*
O
F
F
3
.
V
.
P
U
L
S
E
*
*
*
*
*
*
*
*
*
*
*
*
O
F
F
*
*
*
*
*
*
*
[
V
T
R
*
M
O
D
E
]
*
*
*
*
*
*
*
1
.
H
D
R
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
O
F
F
2
.
C
N
T
*
M
E
M
*
S
W
*
*
*
*
*
*
*
*
*
O
F
F
3
.
P
O
W
E
R
*
O
N
*
R
E
C
*
*
*
*
*
*
*
O
F
F
4
.
A
U
T
O
*
R
E
C
*
C
H
E
C
K
*
*
*
*
*
O
F
F
5
.
A
U
T
O
*
R
E
W
*
*
*
*
*
*
*
*
*
*
*
O
F
F
6
.
R
E
P
E
A
T
*
P
L
A
Y
*
*
*
*
*
*
*
*
O
F
F
7
.
R
E
P
E
A
E
*
R
E
C
*
*
*
*
*
*
*
*
*
O
O
N
Set to "ON".
ALARM/SENSOR MODE screen
*
*
*
*
*
[
S
R
I
/
E
X
T
*
M
O
D
E
]
*
*
*
*
*
1
.
S
R
I
/
E
X
T
*
R
E
C
*
*
*
*
*
*
*
*
O
F
F
2
.
E
X
T
*
R
E
C
*
E
N
D
*
*
*
*
*
N
O
R
M
A
L
3
.
C
N
T
*
T
A
P
E
S
E
N
D
*
*
*
*
*
*
*
O
F
F
*
*
[
A
L
A
R
M
/
S
E
N
S
O
R
*
M
O
D
E
]
*
*
*
1
.
R
E
C
*
M
O
D
E
*
*
*
*
*
*
*
*
S
E
N
S
O
R
2
.
R
E
C
*
S
P
E
E
D
*
*
*
*
*
*
*
*
*
*
*
2
H
3
.
D
U
R
A
T
I
O
N
*
*
*
*
*
*
*
*
1
6
0
S
E
C
4
.
T
A
P
E
*
E
N
D
*
M
O
D
E
*
*
*
*
*
*
O
F
F
Set to "OFF"
5
.
A
U
T
O
*
R
E
W
*
*
*
*
*
*
*
*
*
*
*
O
F
F
6
.
R
E
P
E
A
T
*
P
L
A
Y
*
*
*
*
*
*
*
*
O
F
F
7
.
R
E
P
E
A
E
*
R
E
C
*
*
*
*
*
*
*
*
*
O
F
F
* When repeat recording is executed, any previously
executed alarm recordings will be erased.
5
When the <AUTO REC CHECK> menu switch is set
to "ON"
Repeat recording
Tape beginning position
Auto recording for
several seconds
Normal
Recording
Recording check
Defect
Auto head
cleaning
Auto recording for
several seconds
Normal
Recording check
Recording
Defect
Auto head
Recording
cleaning
Display
The error code "E-09"
remains on the display.
43

Advertisement

Table of Contents
loading

Table of Contents