Connecting Condensate Drain Line - Carrier 53KHET 12 Installation Manual

Hi wall split air conditioners
Hide thumbs Also See for 53KHET 12:
Table of Contents

Advertisement

17.

CONNECTING CONDENSATE DRAIN LINE

17-1 SIZE OF CONDENSATE DRAIN LINE
The condensate drain line (not supplied) for indoor unit must be made of PVC piping with an inside
diameter of 5/8" (16 mm) and have suitable length for the chosen installation site.
17-2 POSSIBLE OUTLET LOCATIONS OF CONDENSATE DRAIN LINE WITH
REFRIGERANT PIPING LINES AND ELECTRICAL CABLES FROM THE INDOOR UNIT
7
5
3
1. Outlet location from unit right back.
2. Outlet location from unit left back.
3. Outlet location from unit right side.
4. Outlet location from unit left side.
5. Plastic cover right side
6. Plastic cover left side
7. Holder
NOTES
8. For the left-hand and right-hand
piping, remove the pipe cover from
the side panel.
9. Explain to the clients that the pipe
cover must be kept as it may be used
when relocate the air conditioner to
any other place
2
1
1
6
4
2
3
Right side
condensate drain line
4
38
Back right
condensate drain line
Back left
condensate drain line
Left side
condensate drain line