Table of contents Installation ..........................4 PIN code ........................4 1.1.1 PIN code deactivated ..................4 1.1.2 PIN code activated .................... 4 Startup .......................... 4 Turn off the GSM Gateway .................... 4 Change SIM card ......................4 Front panel connectors and indications ................... 5 Back panel connectors and indications ..................
Page 3
SIM PIN code Activated or deactivated PIN code ACTIVATED DEACTIVATED Set PIN Turn of code to: PIN code 1234 lock CONNECTIONS Insert the SIM card, connect the antenna, autodialler ECII™ Flex and Power 230 VAC Power Supply 12-24 VDC ANTENNA …...
1. Installation Find a suitable place where to mount the GSM gateway following these guide lines: Make sure the GSM coverage is good before the GSM gateway is mounted. Place the Gateway near a window if possible. Make sure the LEDs on both sides are visible. ...
2. Front panel connectors and indications PHONE USB 2.0 Mini connector to be used for connection with a PC. The USB can be used for updating the software of the GSM Gateway and also for adjusting parameters, such as battery tripping limits. For more information please see section 6 “Upgrade Tool”. LED Indicators Status Indicates...
3. Back panel connectors and indications 12V DC SMA connector for the antenna Input of the SIM card Status for the GSM connection when the GSM Gateway is up and running (Green LED): Indicates Faulty GSM unit 800 ms ON / 800 ms OFF No service, No connection with GSM network or SIM-card missing.
4. Battery The battery is supervised in two different ways. The first “low battery voltage indication” is activated when the battery voltage is too low for any reason. The second is a “battery fault alarm” activated when the battery capacity is too low and it is time to replace the battery. In case there is a battery alarm/low battery voltage indication, the GSM Gateway will change the dial tone;...
5. SMS functionality Note: The symbol means new line. 5.1 Low battery voltage indication It is possible to generate an SMS when a Low battery voltage indication occurs; the functionality is activated by sending an SMS to the GSM Gateway. The SMS must include the telephone number and an alarm text.
Bares:On Battery V level OK from Lift 452 Bares:On Battery V level OK from Lift 452 SMS to GSM Gateway SMS from GSM Gateway The GSM Gateway will acknowledge a correct programming by returning a SMS as above. In this example when the power to the Gateway is reestablished and the battery voltage is above the set voltage level the following SMS from the GSM Gateway: Battery V level OK from Lift 452 SMS from GSM Gateway...
Dial tone2:off Dial Tone2: OFF SMS to GSM Gateway SMS from GSM Gateway To reactivate the dial tone 2 (battery alarm/low battery voltage indication, dial tone); send the left side SMS to the GSM Gateway. The Gateway will return the answer on the right side. Dial tone2:on Dial Tone2: ON SMS to GSM Gateway...
Last restart reason xxx1 Power on xx1x External reset x1xx Watch-dog reset 1xxx Low voltage reset Current operator in use, in text format Cell ID of the base station Location area code of network cell Line POTS line On-hook or Off-hook LHoff Time since last hook-off, presented in days, hours and minutes 6.
Click on “Select file” Brows to find and select the new FW file supplied by FältCom or your local distributor. Note: The FW file always has the file extension bin (e.g. gatewayFW.bin). Click on “Update”. During the update you can follow the progress in the status bar. Note: Be careful not to disconnect the power during FW upgrade.
6.2.1 LED control on signal strength There are two LED’s showing the strength of the GSM signal; S1 and S2. You can set the limits when to light these LED’s. 6.2.2 Battery control The GSM Gateway can be used with or without battery backup. The default setting is battery Mounted and Battery fault alarm enabled.
6.2.4 GSM SMS Access code Change the SMS Access code. The SMS Access code is used an authorisation code to allow the Gateway to send SMS to the user. If the Access code in the SMS sent to the Gateway is incorrect the Gateway will not answer the SMS.
Page 15
tone. The Dial tone battery alarm is 1000ms ON / 250ms OFF / 250ms ON / 250ms OFF. To configure this setting set: “Dial/Congestion tone, battery fault” to “Dial tone battery alarm”. This setting is default active. The emergency alarm must be programmed accordingly in order to detect the battery fault alarm signal from the Gateway;...
7. Technical Data Parameter: Data: Size (L x B x H): 165 x 140 x 25 mm Weight: 558 g, with battery and antenna included Protection class: IP 20 External power: 10-28 VDC Power consumption At rest: 12V < 180mA, 24V < 95mA Ongoing call: 12V <...