How To Connect Tank Unit Thermistor Cable - Sanden GAUS-315EQTA Installation Manual

Heat pump with natural refrigerant (co2)
Hide thumbs Also See for GAUS-315EQTA:
Table of Contents

Advertisement

How to connect tank unit thermistor cable 
Cut the thermistor cable and conduit to the required lengths. The thermistor cable and
conduit length are designed to cover the maximum allowable distance between the
tank unit and heat pump unit (four meters). If the units are located closer than four
meters the thermistor cable and conduit may be cut to the desirable length (Figure 11).
Reveal the sheath on the thermistor cable.
Attach the conduit connector to the conduit end. Push the conduit into the opening on
the connector until the conduit does not go any further. Pull the conduit several times
to ensure the connector is fixed properly to the conduit.
Unscrew and firmly remove the terminal block cover. Do not use unnecessary force to
remove the cover as this could pull and break the cable coming out of the tank unit.
Join the connector on the end of the thermistor conduit coming from the heat pump
unit side to the opening on the bottom of the cover on the tank unit. Confirm the gasket
is attached to the tread of the conduit connector before joining the connector to the
cover. If the gasket is not attached, there is a risk of water getting inside the cover and
this may result in a malfunction of the terminal block.
Connect the thermistor cable to the bottom of the terminal block.
Put the terminal block cover back onto the tank unit and tighten the screws.
Figure 11: Connect tank unit thermistor cable
 
 
Tank unit 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Sanden Heat Pump – Installation Manual 
Page 13 of 26 
Terminal 
block
Thermister 
cable
Gasket 
Conduit 
connecto
Conduit